Detrimental Immediate- and Medium-Term Clinical Effects of Right Ventricular Pacing in Patients With Myocardial Fibrosis.

Circ Cardiovasc Imaging

Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, United Kingdom (C.E.D.S., M.F.P., L.A.E.B., J.G., P.G.C., A.D., T.P.C., A.C., A.K., E.L., E.D., K.K.W., J.P.G., S.P., P.P.S.).

Published: May 2021

Background: Long-term right ventricular (RV) pacing leads to heart failure or a decline in left ventricular (LV) function in up to a fifth of patients. We aimed to establish whether patients with focal fibrosis detected on late gadolinium enhancement cardiovascular magnetic resonance (CMR) have deterioration in LV function after RV pacing.

Methods: We recruited 84 patients with LV ejection fraction ≥40% into 2 observational CMR studies. Patients (n=34) with a dual-chamber device and preserved atrioventricular conduction underwent CMR in 2 asynchronous pacing modes (atrial asynchronous and dual-chamber asynchronous) to compare intrinsic atrioventricular conduction with forced RV pacing. Patients (n=50) with high-grade atrioventricular block underwent CMR before and 6 months after pacemaker implantation to investigate the medium-term effects of RV pacing.

Results: The key findings were (1) initiation of RV pacing in patients with fibrosis, compared with those without, was associated with greater immediate changes in both LV end-systolic volume index (5.3±3.5 versus 2.1±2.4 mL/m; <0.01) and LV ejection fraction (-5.7±3.4% versus -3.2±2.6%; =0.02); (2) medium-term RV pacing in patients with fibrosis, compared with those without, was associated with greater changes in LV end-systolic volume index (8.0±10.4 versus -0.6±7.3 mL/m; =0.008) and LV ejection fraction (-12.3±7.9% versus -6.7±6.2%; =0.012); (3) patients with fibrosis did not experience an improvement in quality of life, biomarkers, or functional class after pacemaker implantation; (4) after 6 months of RV pacing, 10 of 50 (20%) patients developed LV ejection fraction <35% and were eligible for upgrade to cardiac resynchronization according to current guidelines. All 10 patients had fibrosis on their preimplant baseline scan and were identified by >1.1 g of fibrosis with 90% sensitivity and 70% specificity.

Conclusions: Fibrosis detected on CMR is associated with immediate- and medium-term deterioration in LV function following RV pacing and could be used to identify those at risk of heart failure before pacemaker implantation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8136461PMC
http://dx.doi.org/10.1161/CIRCIMAGING.120.012256DOI Listing

Publication Analysis

Top Keywords

pacing patients
12
ventricular pacing
8
atrioventricular conduction
8
underwent cmr
8
patients
7
pacing
5
detrimental immediate-
4
immediate- medium-term
4
medium-term clinical
4
clinical effects
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!