A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantification of ribociclib in dried blood spots by LC-MS/MS: Method development and clinical validation. | LitMetric

Quantification of ribociclib in dried blood spots by LC-MS/MS: Method development and clinical validation.

J Pharm Biomed Anal

Department of Medical Oncology, Erasmus MC Cancer Institute, Rotterdam, The Netherlands; Department of Hospital Pharmacy, Erasmus University Medical Center, Rotterdam, The Netherlands.

Published: July 2021

A reliable, specific, selective and robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of ribociclib in both dried blood spot (DBS) samples and potassium EDTA plasma. DBS samples were obtained simultaneously with a plasma sample in advanced breast cancer patients treated with ribociclib. A 6 mm disk from the central part of the dried blood spot sample was punched, followed by extraction of ribociclib using liquid-liquid extraction spiked with ribociclib-d6 as internal standard. Concentrations of ribociclib in DBS samples were correlated with corresponding plasma concentrations. From the blood sample also hematocrit was determined. The method was validated for selectivity, sensitivity, precision, lower limit of detection, linearity, stability and accuracy according to the food and drug administration (FDA) guideline. The within- and between-run precisions were ≤10.6 and ≤1.07 %, respectively; while the average accuracy ranged from 100 to 103 %. The influence of hematocrit on validation parameters was tested in the range of 0.20 - 0.40 L/L. No influence of hematocrit on validation parameters was observed. Regression analysis and a Bland-Altman plot indicated correlation between the results obtained from DBS and plasma samples. A strong correlation (R >0.97) between DBS samples and plasma concentration from 17 breast cancer patients was found. A number of 12 out of 17 processed DBS samples (71 %) fell inside the acceptable range of 20 % difference of simultaneously obtained plasma samples. The lower limit of quantification in DBS is 10.0 ng/mL and linearity was demonstrated up to 1000 ng/mL. In conclusion, the newly developed assay met the required standard for validation. The methods were used to study ribociclib disposition in patients with advanced breast cancer.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2021.114118DOI Listing

Publication Analysis

Top Keywords

dbs samples
20
dried blood
12
breast cancer
12
ribociclib dried
8
lc-ms/ms method
8
blood spot
8
simultaneously plasma
8
advanced breast
8
cancer patients
8
lower limit
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!