Severity: Warning
Message: file_get_contents(https://...@pani&datetype=edat&usehistory=y&retmax=5&tool=pubfacts&email=info@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
An SeS-loaded Co MOF and Au@PANI nanocomposite comprising the base matrix of the electrode was developed with electropolymerized molecularly imprinted polymer (MIP) consisting of p-aminobenzoic acid (PABA) and patulin (PT) to detect PT molecules based on the PT imprinted cavities. SeS@Co MOF and Au@PANI were synthesized using hydrothermal synthesis and interfacial polymerization strategies, respectively. A suitable functional monomer to fabricate the MIP platform was selected using the density functional theory (DFT/M06-2X method). Higher electrochemical active surface area (0.985 cm which is 6.99 times higher than the bare SPE) and a lower charge transfer resistance (R = 27.8 Ω) at the MIP/Au@PANI/SeS@Co MOF electrode was achieved based on the higher number of adsorptive sites and enhanced conductivity (electron transfer rate constant (k = 3.24 × 10 s) of the sensing platform. The fabricated MIP sensor performance was studied in 10 mM PBS (pH = 6.4), where an improved detection limit (0.66 pM) for PT and a broad logarithmic linear dynamic range (0.001-100 nM) were both observed. The sensor possessed higher selectivity (Imprinting factor = 15.4 for PT), excellent reusability (%RSD of 10 cycles = 2.49%), high storage stability (6.7% lost after 35 days), and robust reproducibility (%RSD = 3.22%) The as-prepared MIP-based PT sensor was applied to detect PT in a real-time apple juice sample (10% diluted with PBS) with a recovery % ranging from 94.5 to 106.4%. The proposed sensor possesses great advantages in terms of cost-effectiveness, providing a simple detection strategy for long-term storage stability, and reversible cycle measurements.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bios.2021.113302 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!