AI Article Synopsis

  • This study analyzes the migration behavior of cementless press-fit stems using EBRA-FCA to predict early implant failure after two years.
  • A retrospective review of 109 stems showed a mean subsidence of 1.8 mm, with collared stems having significantly less subsidence than collarless stems.
  • The findings suggest that low subsidence and the migration pattern of collared stems indicate potential for good long-term stability in hip implants.

Article Abstract

Purpose: Uncemented stem migration analysis by EBRA-FCA (Einzel-Bild-Roentgen Analyse, Femoral Component Analysis) has been seen to be a good predictive indicator for early implant failure. In this study, we investigated the migration behavior of a cementless press-fit stem after two years follow-up. Stem type and postoperative gap between collar and femur were evaluated as a risk factor.

Methods: Applying a retrospective study design, we reviewed all consecutive patients who between 2013 and 2017 received a cementless press-fit Corail stem (DePuy Orthopaedics Inc., Warsaw, IN, USA) at our Department. We reviewed medical histories and performed radiological measurements using EBRA-FCA software.

Results: A total of 109 stems in 105 patients (female: 60; male: 45) fulfilled our inclusion criteria. Mean age at surgery was 67.8 (range, 21.6-90.5) years. EBRA migration analysis showed a mean subsidence of 1.8 mm (range, 0.0-12.1) at final follow-up. At 18 months mean subsidence of collared stems was significantly lower than in the collarless group [1.3 mm (range, 0.0-7.6) vs. 3.2 mm (range, 0.5-10.7), p = 0.0104]. Collared stems resting on the femoral cut presented a tendency to less subsidence than did collared stems showing a postoperative gap between collar and femur (1.3 vs. 2.0 mm) without finding statistical significance (p > 0.05).

Conclusions: Low subsidence and the migration pattern of the cementless press-fit stem may predict a good long-term result. Collared stems investigated in our study provide good stability and are able to prevent significant subsidence. Trial registration number and date of registration: Number: 20181024-1875; Date: 2018-10-24.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8843908PMC
http://dx.doi.org/10.1007/s00402-021-03926-9DOI Listing

Publication Analysis

Top Keywords

collared stems
16
cementless press-fit
12
migration analysis
8
press-fit stem
8
postoperative gap
8
gap collar
8
collar femur
8
subsidence collared
8
registration number
8
migration
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!