In this work we propose a generic modeling approach for simulating percutaneous transluminal angioplasty (PTA) endovascular treatment, and evaluating the influence of balloon design, plaque composition, and balloon sizing on acute post-procedural outcomes right after PTA, without stent implantation. Clinically-used PTA balloons were classified into two categories according to their compliance characteristics, and were modeled correspondingly. Self-defined elastoplastic constitutive laws were implemented within the plaque and artery models, after calibration based on experimental and clinical data. Finite element method (FEM) implicit solver was used to simulate balloon inflation and deflation. Besides balloon profile at max inflation, results are mainly assessed in terms of the elastic recoil ratio (ERR) and lumen gain ratio (LGR) obtained immediately after PTA. No variations in ERR nor LGR values were detected when the balloon design changed, despite the differences observed in their profile at max inflation. Moreover, LGR and ERR inversely varied with the augmentation of calcification level within the plaque (-11% vs. +4% respectively, from fully lipidic to fully calcified plaque). Furthermore, results showed a direct correlation between balloon sizing and LGR and ERR, with noticeably higher rates of change for LGR (+18% and +2% for LGR and ERR respectively for a calcified plaque and a balloon pressure increasing from 10 to 14 atm). However a larger LGR comes with a higher risk of arterial rupture. This proposed methodology opens the way for evaluation of angioplasty balloon selections towards clinical procedure optimization.

Download full-text PDF

Source
http://dx.doi.org/10.1002/cnm.3499DOI Listing

Publication Analysis

Top Keywords

balloon design
12
balloon sizing
12
lgr err
12
balloon
9
influence balloon
8
design plaque
8
composition balloon
8
sizing acute
8
finite element
8
profile max
8

Similar Publications

Voxel-based morphometry (VBM) of T1-weighted (T1-w) magnetic resonance imaging (MRI) is primarily used to study the association of brain structure with cognitive functions. However, in theory, T2-weighted (T2-w) MRI could also be used in VBM studies because of its sensitivity to pathology and tissue changes. We aimed to compare the T1-w and T2-w images to study brain structures in association with cognitive abilities.

View Article and Find Full Text PDF

Purpose: To assess differences in safety and efficacy between 24 and 18 Fr pneumatic balloon dilators for percutaneous nephrolithotripsy (PCNL) of renal stones between 10 and 20 mm.

Methods: Patients were randomized to dilatation with a 24 Fr (Group A) versus 18 Fr (Group B) Ultraxx pneumatic dilator (Cook Medical). In all procedures percutaneous puncture was performed under ultrasound guidance.

View Article and Find Full Text PDF

Novel CO loaded nanoparticle ultrasound-activated contrast agent: A potential urinary catheter-free modality to detect vesicoureteral reflux.

J Pediatr Urol

January 2025

Division of Urology, Children's Hospital Los Angeles, USC Institute of Urology, Keck School of Medicine of USC, Los Angeles, CA, USA. Electronic address:

Background: The current gold-standard for detecting vesicoureteral reflux (VUR) is the voiding cystourethrogram (VCUG). However, VCUGs require ionizing radiation and bladder catheterization that can be challenging to perform and traumatic for pediatric patients and their parents.

Objective: To investigate the feasibility of a novel urinary catheter-free modality for diagnosing VUR using in vitro and ex vivo models.

View Article and Find Full Text PDF

The intra-aortic balloon pump (IABP) is a widely-used mechanical circulatory support device that enhances hemodynamics in patients with heart conditions. Although the IABP is a common clinical tool, its effectiveness in enhancing outcomes for patients with acute myocardial infarction and cardiogenic shock remains disputed. This study aimed to assess the effectiveness of intra-aortic dual-balloon pump (IADBP) and its impact on aortic hemodynamics compared with an IABP.

View Article and Find Full Text PDF

Background: As induction of labor increases in the United States, safe, effective outpatient cervical ripening has been explored as a method to decrease the inpatient time burden. The most effective method of outpatient mechanical cervical ripening remains unclear.

Objective: To evaluate if Dilapan-S is non-inferior to cervical balloon for outpatient cervical ripening (CR) based on change in Bishop score.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!