Background: The aesthetics and strength of anterior porcelain layered zirconia (PLZ) crowns are mainly affected by the zirconia (Zr) coping design. There is a need for a modified design to enhance aesthetics with strength.

Objectives: The purpose of this study was to compare the fracture resistance of anterior PLZ crowns having modified CAD-CAM Zr coping designs (in terms of thickness and marginal collar designs) with standard Zr copings.

Methods: Fifty PLZ crowns were fabricated and divided into two groups: Gr 1: Standard Zr Coping (SZC) (control gr) with 0.5 mm thickness (Facial-F, Mesial-M, Distal-D, incisal-I, and Palatal-P) without a collar; Gr 2: Collar Zr Coping (CZC) (test gr) with 2.5 mm collar height on M, D, P and 0.2 mm F and variable facial wall thickness. Subgroups: Gr 2a: (CZC-0.5 mm) facial wall thickness 0.5 mm; Gr 2b: (CZC-0.4 mm) facial wall thickness 0.4 mm; Gr 2c: (CZC-0.3 mm) facial wall thickness 0.3 mm; Gr 2d: (CZC-0.2 mm) facial wall thickness 0.2 mm. The fracture load was determined and analysed using One-way ANOVA and Dunnet test.

Results: The minimum fracture load was 927.36 ± 127.80 N observed for Gr 2c (CZC at 0.3 mm) while the maximum fracture load was 1373.61 ± 146.54 N observed for Gr 2a (CZC at 0.5 mm). A highly significant difference in mean fracture load among various Zr coping groups (p< 0.001) was determined.

Conclusions: Novel Zr coping design for anterior PLZ crowns can provide better aesthetics with strength. Reducing the thickness of Zr coping in the aesthetic zone to 0.2 mm and providing a modified collar design (2.5 mm collar height on M, D, P, and 0.2 mm F) would provide strength without jeopardizing aesthetics.

Download full-text PDF

Source
http://dx.doi.org/10.3233/THC-202782DOI Listing

Publication Analysis

Top Keywords

plz crowns
20
facial wall
20
wall thickness
20
fracture load
16
coping design
12
aesthetics strength
12
anterior plz
12
coping
8
zirconia coping
8
design enhance
8

Similar Publications

Article Synopsis
  • * Data collected from 240 patients in Europe indicates a median overall survival of 14.6 months following the start of initial BTKi therapy, with varying outcomes based on subsequent treatments.
  • * Patients who received further therapy after BTKi failure had a median overall survival of 23.8 months, particularly with lenalidomide and bendamustine plus rituximab, providing a new benchmark for treatment effectiveness.
View Article and Find Full Text PDF

Background: The aesthetics and strength of anterior porcelain layered zirconia (PLZ) crowns are mainly affected by the zirconia (Zr) coping design. There is a need for a modified design to enhance aesthetics with strength.

Objectives: The purpose of this study was to compare the fracture resistance of anterior PLZ crowns having modified CAD-CAM Zr coping designs (in terms of thickness and marginal collar designs) with standard Zr copings.

View Article and Find Full Text PDF

To investigate the effect of luting agent type on fracture loads of implant-supported ceramic prostheses in premolar region. Ninety-nine implant-abutment complexes were divided into three different implant-supported prostheses: monolithic yttria-partially stabilized zirconia (Y-PSZ) restorations (MPZ specimens), porcelain layered on yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) restorations (PLZ specimens), and monolithic lithium disilicate ceramic restorations (MLD specimens). Implant-supported prostheses were luted with adhesive resin luting agent (RLA), glass ionomer cement (GIC), or zinc phosphate cement (ZPC).

View Article and Find Full Text PDF

Objectives: The objective of this in vitro study was to investigate fracture loads of screw-retained zirconia-based molar restorations (hybrid abutment crown) fabricated with different restorative materials and designs.

Material And Methods: Forty-four screw-retained zirconia-based molar restorations were fabricated on dental implants and divided into four groups (n = 11): porcelain-layered zirconia-based restorations (PLZ), indirect composite-layered zirconia-based restorations (ILZ), metal-ceramic restorations (MC), and monolithic zirconia restorations (MONO). The zirconia-based restorations in the PLZ, ILZ, and MONO groups were adhesively bonded on implant abutments with a dual-polymerized resin material.

View Article and Find Full Text PDF