Ulnar collateral ligament (UCL) weakening or tears occur in 16% of professional baseball pitchers. To prevent players from sustaining a UCL injury, it is important to understand the relationship between the UCL properties and elbow stabilizers with the load on the UCL during pitching. In-vitro studies showed that the ultimate external valgus torque of 34 Nm would rupture the UCL, which is in apparent conflict with the reported peak valgus torques in pitching (40-120 Nm). Assuming both observations are correct, the question rises why 'only' 16 out of 100 professional pitchers sustain a UCL rupture. Underestimation of the effect of other structures in in-vivo studies is most likely the explanation of this mismatch because the calculated in-vivo torque also includes possible contributions of functional and structural stabilizers. In-vitro studies show that the flexor-pronator mass has the potential to counteract valgus torque directly, whereas the elbow flexor-extensor muscles combined with the humeroradial joint might have an indirect effect on valgus torque by increasing the joint compression force. Accurate experimental electromyography data and a more detailed (musculoskeletal)mechanical model of the elbow are needed to investigate if and to what extent the structural and functional stabilizers can shield the UCL during pitching.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8130712PMC
http://dx.doi.org/10.1080/23335432.2021.1916405DOI Listing

Publication Analysis

Top Keywords

valgus torque
12
ulnar collateral
8
collateral ligament
8
in-vivo studies
8
ucl pitching
8
in-vitro studies
8
ucl
7
ligament loading
4
loading paradox
4
paradox in-vitro
4

Similar Publications

Benefits of Using Functional Joint Coordinate Systems in In Vitro Knee Testing.

J Biomech Eng

January 2025

Department of Biomedical Engineering and Lerner Research Institute, Cleveland Clinic, 2111 E. 96th Street, Cleveland, OH 44106.

To measure knee joint kinematics, coordinate systems (CS) must be assigned to the tibia and femur. Functional CS have been shown to be more reproducible than Anatomical. This study aims to quantify the benefits of using Functional CS in in vitro testing.

View Article and Find Full Text PDF

Purpose: The medial collateral ligament (MCL), and posterior oblique ligament (POL) are the primary valgus stabilisers of the knee, and clinical examinations in grading valgus instability can be inherently subjective. Stress radiography of medial-sided knee injuries provides objective diagnosis and was analysed in this study. We hypothesised that (1) medial joint space opening would increase cutting the superficial MCL (sMCL), POL and anterior cruciate ligament (ACL); (2) isolated deep MCL (dMCL) injury would not increase medial joint space opening; (3) medial joint space opening would increase at higher flexion angles.

View Article and Find Full Text PDF

Objective: To investigate the protective effects of ankle braces in patients with functional ankle instability.

Methods: This retrospective study involved 30 participants recruited from January 2023 to December 2023 at School of Physical Education, Nanchang University. These participants were divided into an ankle brace group wearing braces and a control group without braces.

View Article and Find Full Text PDF

Meniscal forces and knee kinematics are affected by tibial slope modifying high tibial osteotomy.

Knee Surg Sports Traumatol Arthrosc

January 2025

Orthopaedic Robotics Laboratory, Departments of Bioengineering and Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.

Purpose: To quantify the effect of increasing the posterior tibial slope (PTS) on knee kinematics and the resultant medial and lateral meniscal forces.

Methods: In this controlled laboratory study, a 6 degrees of freedom (DOF) robotic testing system was used to apply external loading conditions to seven fresh-frozen human cadaveric knees: (1) 200-N axial compressive load, (2) 5-N m internal tibial +10-N m valgus torque and (3) 5-N m external tibial + 10-N m varus torque. Knee kinematics and the resultant medial and lateral meniscal forces were acquired for two PTS states: (1) native PTS and (2) increased PTS.

View Article and Find Full Text PDF

[Biomechanical study of screw implant angle in reconstruction of tibiofibular syndesmosis injury].

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi

December 2024

Department of Orthopedics, the Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou Sichuan, 646000, P. R. China.

Objective: To investigate ideal screw implant angle in reconstruction of tibiofibular syndesmosis injury by using a biomechanical test.

Methods: A total of 24 ankle specimens from adult cadavers were used as the tibiofibular syndesmosis injury model. According to the angle of screw placement, the tibiofibular syndesmosis injury models were randomly divided into groups A (0°), B (10°-15°), C (20°-25°), and D (30°-35°), and the screws were placed at a level 2 cm proximal to the ankle joint.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!