Cadaveric Evaluation of Load to Failure in Canine Gingiva Apposed With Varied Suture Patterns Using Poliglecaprone 25.

J Vet Dent

Small Animal Surgery, Department of Clinical Sciences, College of Veterinary Medicine, Colorado State University, Fort Collins, CO, USA.

Published: March 2021

The purpose of the study was to determine the effect of suture pattern and repair length on the load to failure in an ex vivo canine gingival model. Healthy mandibular gingiva and mucosa were harvested from fresh cadavers euthanized for purposes unrelated to the study. Samples were randomly assigned by length and pattern. Lingual and buccal free gingival margins were apposed using a simple interrupted (SI), cruciate (XT), simple continuous (SC), or unidirectional knotless continuous barbed suture (SF) closure technique with USP 4-0 poliglecaprone 25 applied over 2 lengths (3 cm and 6 cm). A custom template was used to ensure uniform suture bite application. Surgical time was recorded. Using a soft tissue mechanical testing frame, samples were tensioned to failure. Testing was video recorded and reviewed in conjunction with the tension trace data for tension at initial failure (T) and maximum tension sustained (T). Two factor ANOVA by length and pattern was performed followed by individual one way T-tests. Statistically significant findings were XT-SC-SF patterns were quicker to perform than SI. SF was more likely to fail by suture breakage than tissue tearing, and SF withstood less tension at the 3 cm length than SI-XT-SC. No significant difference was detected in T or T between SI and SC or XT. The study demonstrates that SC and XT are comparable to SI in tension resistance and faster to perform suggesting that SC and XT could replace SI for extraction site closure although further in vivo testing is required.

Download full-text PDF

Source
http://dx.doi.org/10.1177/08987564211010940DOI Listing

Publication Analysis

Top Keywords

load failure
8
length pattern
8
suture
5
tension
5
cadaveric evaluation
4
evaluation load
4
failure
4
failure canine
4
canine gingiva
4
gingiva apposed
4

Similar Publications

Crestal placement of short plateau implants in compromised jaws may cause implant failure due to bone overstress. The aim was to evaluate the impact of different sized implants on adjacent bone overload and the implant load-bearing ability in terms of the proposed index-ultimate functional load (UFL). Three-dimensional models of osseointegrated implants placed in types III and IV bone were analysed by the FEM for the case of patient-specific variations in cortical bone elasticity modulus.

View Article and Find Full Text PDF

This study investigated the compressive behavior of 30 vol.% boron carbide (BC)/2024 aluminum (Al) composites under quasi-static and dynamic loading at different temperatures. Building on the experimental findings, the Johnson-Cook (JC) model was modified, and a complete failure criterion was proposed.

View Article and Find Full Text PDF

This study investigated the axial tensile performance of adhesively bonded T700/C204 carbon fiber composite and TC4 titanium alloy tubular single-lap joints under three distinct temperature conditions: room temperature, low temperature (-65 °C), and room-low-room-temperature cycling. Two configurations of adhesively bonded joints-composite-composite and composite-titanium-were tested. Specimens were designed to evaluate the influence of spew-fillet and perfect lap configurations on uniaxial tensile bonding strength across varying temperature environments.

View Article and Find Full Text PDF

Improving Eco-Friendly Polymer Adhesive Joints: Innovative Toughening Strategies for Consistent Performance Under Various Loading Conditions.

Polymers (Basel)

February 2025

Departamento de Engenharia Mecânica, Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal.

In modern engineering applications, the use of sustainable materials and eco-friendly methods has become increasingly important. Wood joints, especially those strengthened with bio-adhesive, have attracted considerable attention due to their inherent environmental benefits and desirable mechanical properties. Compared to traditional joining methods, adhesive joints offer unique advantages such as improved load distribution, reduced stress concentration, and enhanced aesthetic appeal.

View Article and Find Full Text PDF

Mechanical metamaterials with high recoverable elastic energy density, which we refer to as high-enthalpy elastic metamaterials, can offer many enhanced properties, including efficient mechanical energy storage, load-bearing capability, impact resistance and motion agility. These qualities make them ideal for lightweight, miniaturized and multi-functional structures. However, achieving high enthalpy is challenging, as it requires combining conflicting properties: high stiffness, high strength and large recoverable strain.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!