The intravascular migration of a multihole epidural catheter can have catastrophic consequences. The consequences can be even more exaggerated if the catheter is placed at the cervical or high thoracic region. We suggest a cautious approach before injection of a bolus of local anaesthetic. Whenever in doubt, the exact position of the catheter should be checked using fluoroscopy and contrast injection. In this case report, we have described our experience with an inadvertently placed intravascular cervical epidural catheter.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8098736PMC
http://dx.doi.org/10.5152/TJAR.2021.119DOI Listing

Publication Analysis

Top Keywords

epidural catheter
12
intravascular migration
8
cervical epidural
8
catheter
5
prompt detection
4
detection intravascular
4
migration cervical
4
catheter superior
4
superior vena
4
vena cava
4

Similar Publications