Tetranor-PGDM is a metabolite of PGD. Urinary tetranor-PGDM levels were reported to be increased in some diseases, including food allergy, Duchenne muscular dystrophy, and aspirin-intolerant asthma. In this study, we developed a monoclonal antibody (MAb) and a competitive enzyme immunoassay (EIA) for measuring tetranor-PGDM. Spleen cells isolated from mice immunized with tetranor-PGDM were utilized to generate Ab-producing hybridomas. We chose hybridomas and purified MAb against tetranor-PGDM to develop competitive EIA. The assay evaluated the optimal ionic strength, pH, precision, and reliability. Specificity was determined by cross-reactivity to tetranor-PGEM, tetranor-PGFM, and tetranor-PGAM. Recovery was determined by spiking experiments on artificial urine. Optimal ionic strength was 150 mM NaCl, and optimal pH was pH 7.5. Metabolites other than tetranor-PGDM did not show any significant cross-reactivity in the EIA. The assay exhibited a half-maximal inhibition concentration (IC) of 1.79 ng/mL, limit of detection (LOD) of 0.0498 ng/mL, and range of quantitation (ROQ) value of 0.252 to 20.2 ng/mL. The intra- and inter-assay variation for tetranor-PGDM was 3.9-6.0% and 5.7-10.4%, respectively. The linearity-dilution effect showed excellent linearity under dilution when artificial urine samples were applied to solid-phase extraction (SPE). After SPE, recovery of tetranor-PGDM in artificial urine averaged from 82.3% to 113.5% and was within acceptable limits (80%-120%). We successfully generated one monoclonal antibody and developed a sensitive competitive EIA. The established EIA would be useful for routine detection and monitoring of tetranor-PGDM in research or diagnostic body fluids.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8096570 | PMC |
http://dx.doi.org/10.1155/2021/5591115 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!