A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Initial experience of a single center with the use of ZSI 475 penile prosthesis. | LitMetric

Objective: To evaluate surgical outcomes after implantation of the Zephyr ZSI 475 inflatable penile prosthesis (IPP) and patients' quality of life.

Methods: From December 2014 to September 2018, 15 patients underwent prosthesis implantation with ZSI 475. A retrospective review of clinical data was performed. Patients' quality of life after implantation was investigated with Quality of Life and Sexuality with Penile Prosthesis (QoLSPP) questionnaire.

Results: The median age of patients was 57 years and the average follow-up time was 22 months. Twelve patients received a standard implantation due to severe erectile dysfunction (ED); three patients also presented penile curvature and additional corporoplasty with grafting was necessary. Three procedures had to be interrupted due to defects of the insertion tools. In one case a manufacturing defect resulted in a pump leak. In one case, a severe postoperative complication occurred, which requested explanation of the device. During the follow-up, four patients experienced mechanical failure of the prosthesis. Results of QoLSPP questionnaire at 12 months were skewed toward the positive end of the scale in all domains.

Conclusion: In our initial experience, ZSI 475 suffered a high rate of mechanical failures; on the other hand, the company showed great commitment in order to improve the quality and reliability of the device. The lower cost of ZSI 475 may add to the chances of the product to become a cost-effective alternative to treat those patient who need a IPP.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8099647PMC
http://dx.doi.org/10.1016/j.ajur.2020.02.002DOI Listing

Publication Analysis

Top Keywords

zsi 475
20
penile prosthesis
12
initial experience
8
patients' quality
8
quality life
8
prosthesis qolspp
8
zsi
5
0
5
prosthesis
5
patients
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!