Medical devices may revolutionize healthcare delivery but can lead to serious adverse events for treated patients and users. While reporting of adverse events related to medical devices is an essential starting point for post-market surveillance, underreporting of medical device adverse events is a global problem. Korea introduced a voluntary medical device adverse event reporting system in 2010, called the Medical Device Safety Information Monitoring Center, which has led to an increase in adverse event reports. For 10 years, the Medical Device Safety Information Monitoring Center has analyzed medical device adverse events systematically and has provided active feedback to the manufacturers and education on safe use. Recently, the Medical Device Safety Information Monitoring Center contributed to harmonization of international medical device vigilance through the sharing of adverse events. This experience of Korea might contribute to improvements in medical device vigilance, which is a critical prerequisite for improving medical device policies and regulations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.healthpol.2021.04.017 | DOI Listing |
J Cardiothorac Surg
January 2025
Department of Cardiothoracic Surgery, Aalborg University Hospital, Hobrovej 18-22, Aalborg, 9000, Denmark.
Background: The outcome of coronary artery bypass grafting (CABG) depends on several factors, including the quality of the distal anastomoses to the coronary arteries. Early graft failure may be caused by, e.g.
View Article and Find Full Text PDFBMC Nurs
January 2025
Department of Adult Health Nursing, College of Health Sciences, Arsi University, Asella, Ethiopia.
Background: Pressure injuries are a significant concern in healthcare settings, leading to increased morbidity, healthcare costs, and patient suffering. This systematic review aims to evaluate the impact of multifaceted interventions on the prevention of Pressure injuries and improvements in nursing practices.
Methods: A systematic search was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines across multiple databases, including studies from Google Scholar (332), Science Direct (14), grey literature sources (45), PubMed (0), Cochrane Library (437), and Hinari (322).
J Neuroeng Rehabil
January 2025
Hulse Spinal Cord Injury Research Lab, Shepherd Center, 2020 Peachtree Road NW, Atlanta, GA, USA.
Background: There is growing interest in use of transcutaneous spinal stimulation (TSS) for people with neurologic conditions both to augment volitional control (by facilitating motoneuron excitability), and to decrease spasticity (by activating inhibitory networks). Various electrode montages are used during TSS, with little understanding of how electrode position influences spinal circuit activation. We sought to identify the thoracolumbar electrode montage associated with the most robust activation of spinal circuits by comparing posterior root-muscle reflexes (PRM reflexes) elicited by 6 montages.
View Article and Find Full Text PDFJ Physiol Anthropol
January 2025
Faculty of Health Sciences, Hokkaido University, Kita 12, Nishi 5, Kita-Ku, Sapporo, Hokkaido, 060-0812, Japan.
Background: Napping during night shifts is a countermeasure against fatigue and sleepiness, which both impact patient safety. However, there is insufficient evidence on how nurses nap, especially concerning their napping quality. This study explored night-shift napping and its associated factors among nurses, considering napping quantity and quality, to mitigate fatigue and sleepiness.
View Article and Find Full Text PDFBMC Emerg Med
January 2025
Wellman Center for Photomedicine, Harvard Medical School, Massachusetts General Hospital, CNY149, 13th St, Charlestown, 02129, MA, USA.
Background: The use of emergency tourniquets among military personnel has helped to dramatically reduce battlefield deaths and has recently gained popularity in the civilian sector. Yet, even well-trained individuals can find it difficult to assess proper tourniquet application. Emergency tourniquets are typically deemed sufficiently tightened through cursory visual confirmation or pulse assessment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!