FSI modeling on the effect of artery-aneurysm thickness and coil embolization in patient cases.

Comput Methods Programs Biomed

Engineering Faculty of University of Porto, Institute of Science and Innovation in Mechanical and Industrial Engineering (LAETA-INEGI), Rua Dr. Roberto Frias, Porto 4200-465, Portugal. Electronic address:

Published: July 2021

Background And Objective: The attainment of a methodology to simulate the hemodynamic in patient-specific cerebral vessels with aneurysms is still a challenge. The novelty of this work is focused on the effect of coil embolization in a realistic cerebral aneurysm, according to the vessel wall thickness and aneurysm thickness, through transient FSI simulations.

Methods: The quality of the mesh for simulations was checked with a specific mesh convergence study; and the numerical methodology was validated using numerical research data of the literature. The model was implemented in ANSYS® software. The total deformation and equivalent stress evolution in the studied cases, before and after coil embolization, were compared. More than 20 different models were employed due to different arterial wall thickness and aneurysm wall thickness combinations.

Results: The obtained results have showed that deformation and stress values are highly influenced with the sac thickness. The thinner sac aneurysm thickness is, the greater deformation and stress are. The results after coil embolization process have highlighted that considering typical values of arterial wall thickness and aneurysm thickness 0.3 mm and 0.15 mm respectively, a deformation reduction around 50% and a stress reduction around 70% can be achieved.

Conclusions: The proposed methodology is a step forward in the personalized medicine, quantifying the aneurysm rupture risk reduction, and helping the medical team in the preoperative planning, or to deciding the optimal treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2021.106148DOI Listing

Publication Analysis

Top Keywords

coil embolization
16
wall thickness
16
thickness aneurysm
12
aneurysm thickness
12
thickness
9
arterial wall
8
deformation stress
8
aneurysm
6
fsi modeling
4
modeling artery-aneurysm
4

Similar Publications

Rupture of the thyrocervical trunk aneurysm into the thoracic cavity does not occur very often. It is an urgent condition due to hemorrhagic shock by massive hemothorax with potentially fatal consequences. Pregnancy and puerperium are additional risk factors for a rupture of the thyrocervical trunk aneurysm in patients with neurofibromatosis and aneurysms.

View Article and Find Full Text PDF

A 73-year-old male with a history of incidentally diagnosed Paget disease of bone affecting the skull and left orbit 2 years prior presented with 3 months of vision loss, proptosis, and periorbital swelling of the OS. Examination showed best-corrected Snellen visual acuity of 20/150 in the affected eye, intact motility, 7 mm of relative proptosis, significant dilated and tortuous "corkscrew" conjunctival vessels, serous choroidal and retinal detachments, optic nerve hyperemia, and venous tortuosity and dilation. Although the bony lesions in the left orbit were stable from 1 year prior on imaging, the diagnostic angiogram demonstrated osseous blush and hypervascularity of the lesion.

View Article and Find Full Text PDF

Purpose: Carotid-cavernous fistulas (CCFs) are treated almost exclusively by endovascular techniques, but the frequency of treatments is limited in smaller centers. We analyzed all CCFs treated in our hospital to determine if high-quality treatment of CCFs can be provided in a medium-volume neurovascular center.

Methods: Retrospective quality-control cohort study.

View Article and Find Full Text PDF

Background: Neuroendovascular treatment of cerebral aneurysms is considered a basic procedure for neurosurgeons and interventional neuroradiologists; however, its critical technical nuances, termed "tacit knowledge," are challenging to impart. This study aimed to evaluate the efficacy of our novel video recording and editing method in enhancing trainees' experience.

Methods: A wearable camera (wearable recording) and multiple media sources in a hybrid operating room (hybrid recording) were used to capture procedural details such as audio and conversation, thus enabling a re-experience.

View Article and Find Full Text PDF

This study aimed to evaluate the efficacy of the single-energy metal artifact reduction (SEMAR) algorithm in reducing metal artifacts and enhancing image quality in contrast-enhanced computed tomography (CT) for patients undergoing endovascular aneurysm repair (EVAR) with coil embolization. Thirty-eight patients (mean age 81.0 ± 6 years; 31 men, 7 women) who underwent contrast-enhanced CT following EVAR and internal iliac artery coil embolization between September 2022 and May 2023 were retrospectively analyzed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!