A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantitative measurements of forward head in college-aged students: A conformational study of intra-rater and inter-rater reliability of a novel Posture Measuring Device. | LitMetric

Introduction: Medical professionals frequently encounter forward head postures (FHP) in the treatment of cervical spine pain. In the clinical setting, FHP measurements are often described subjectively using the phrase, "patient demonstrates forward head posture." There are reliable tools that can objectively measure FHP, but they are not frequently used in the clinical setting on a regular basis because the tools are unavailable, inconvenient or overly time-consuming. The objective of this study was to confirm if FHP can be reliably measured using a novel posture-measuring device. The Posture Measuring Device (PMD) was designed to quickly obtain objective measurements of FHP in the outpatient clinical setting. A pilot study demonstrated good to excellent reliability in intra-rater (test-retest) measurements and good interrater reliability using two first-year Doctor of Physical Therapy Students as raters. This study is to confirm that the PMD is able to provide intra-rater and interrater reliability using two physical therapists and two second-year Doctor of Physical Therapy students to obtain FHP measurements.

Methods: Twenty-three college-aged subjects were measured individually using a PMD by a panel of four raters consisting of two physical therapists and two second-year physical therapy students to develop interrater reliability. Each rater measured each subject twice on two separate occasions to obtain a measure of intra-rater (relative) reliability.

Results: Pearson Correlations demonstrate high intra-rater correlation with inconsistent interrater correlation. The average measured Intraclass Correlation Coefficient (ICC) was .822 with a 95% confidence interval indicating a high degree of reliability between the eight measurements performed on each subject. Cronbach's alpha results confirm the ICC findings of strong correlation among the eight raters (α = 0.87).

Discussion And Conclusion: Objective measurement of forward head posture is valuable to document and monitor patient response to treatment. This study identifies a convenient and time-efficient method for measuring forward head in the clinical setting. The PMD demonstrated a high degree of reliability in intra-rater measurements of FHP.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbmt.2020.12.008DOI Listing

Publication Analysis

Top Keywords

forward head
20
clinical setting
16
interrater reliability
12
physical therapy
12
therapy students
12
posture measuring
8
measuring device
8
study confirm
8
measurements fhp
8
reliability intra-rater
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!