Objectives: The aim of this study was to describe an alternative landmark for screw insertion into the body of the ilium with bilateral sacroiliac luxation in cats.

Methods: Seven cat cadavers with artificially induced bilateral sacroiliac luxation were used. The screw insertion point was determined using the caudal iliac crest and cranial acetabular rim. These two points make the first guideline; a second guideline ran perpendicular to the caudal iliac crest point. The screw insertion point was halfway along the second guideline across the ilium body. Surgery was performed in a minimally invasive manner using fluoroscopy.

Results: Postoperative radiographs and CT were performed. In the postoperative evaluation, the sacroiliac joint reduction percentage was almost 90% and there was no significant difference in pelvic canal diameter ratio before and after surgery. Screw depth/sacral width was >60% in all cadavers. On CT, the angle between the screw and sacrum wing was within the normal range of 96.24° to the left and 98.65° to the right, except in one case.

Conclusions And Relevance: In previous studies, surgical repair was based on having an intact contralateral ilium. However, this method is not applicable to patients with bilateral sacroiliac luxation and is mostly performed using open reduction methods. The screw insertion point suggested in this study offers a potential alternative repair technique for patients with bilateral sacroiliac luxation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10812166PMC
http://dx.doi.org/10.1177/1098612X211010724DOI Listing

Publication Analysis

Top Keywords

screw insertion
20
bilateral sacroiliac
20
sacroiliac luxation
20
insertion point
12
minimally invasive
8
repair technique
8
induced bilateral
8
caudal iliac
8
iliac crest
8
second guideline
8

Similar Publications

[Treatment with TOPS for short femoral stump].

Oper Orthop Traumatol

January 2025

Klinik für Unfall‑, Hand und Wiederherstellungschirurgie, Universitätsmedizin Rostock, Schillingallee 35, 18057, Rostock, Deutschland.

Objective: Treatment with transcutaneous osseointegrated prosthesis systems (TOPS) for short femoral amputation stumps aims to restore independent walking ability after proximal femoral amputation by direct bone-guided prosthesis anchorage. This cannot be safely achieved with conventional socket prostheses due to the mechanically inadequate socket contact surface.

Indications: Treatment of patients with short transfemoral stumps who cannot be mobilized sufficiently with conventional socket prostheses.

View Article and Find Full Text PDF

Background: Pedicle screw insertion in posterior spinal surgery can cause vascular injuries, including rare intercostal artery pseudoaneurysms, which are typically discovered incidentally during reimaging. Onyx embolization is an effective treatment for small artery pseudoaneurysms.

Observations: A 36-year-old man who had initially presented with back pain that remained unresponsive to nonsteroidal anti-inflammatory drugs was diagnosed with a T7-8 sarcomatous lesion confirmed by magnetic resonance imaging and biopsy.

View Article and Find Full Text PDF

Evaluation of frictional wear in a follow-up screw-rod kinematic node in GGS transpedicular stabilization.

Acta Bioeng Biomech

September 2024

Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Wrocław, Poland.

: The aim of this study was to evaluate the abrasive wear of the sliding screw-rod joint used in growth guidance system (GGS) stabilizers, allowing for the translation of the screw along the rod during the spinal growth process in a standard and modified system. : The study used single kinematic screw-rod pairs made of titanium alloy Ti6Al4V. Mechanical tests (cyclic loads) simulated the stabilizer's operation under conditions similar to actual use.

View Article and Find Full Text PDF

Orthopedic screws are widely used to achieve bone reduction, compression, and construct stability. However, the relationship between insertion torque, interfragmentary compression, and fixation strength, especially when comparing standard screws with NiTiNOL/sustained dynamic compression (SDC), has not been thoroughly investigated. This study measured insertion torque, interfragmentary compression, and fixation strength for two types of headed orthopedic devices-standard and SDC-using solid foam bone replicates and cadaver validation.

View Article and Find Full Text PDF

Purpose: The fixation method commonly employed worldwide for treating unstable fractures of the posterior pelvic ring is the percutaneous iliosacral screw technique. However, prolonged operation time and frequent fluoroscopies result in surgical risks. This study aimed to investigate whether a new triangulation method could reduce operative and fluoroscopy times and increase the accuracy of screw placement.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!