Background: Sinus lift with a simultaneous implant placement in the residual maxilla is a common technique used worldwide. Nevertheless, choosing an ideal grafting material remains an object of dispute. The use of an autologous blood-derived graft, known as platelet-rich fibrin (PRF), has not yet been recognized to be as good as xenografts and alloplastic materials. However, initial results have been promising.

Objectives: To conduct a clinical and radiological comparison of implantation with a simultaneous sinus lift using xenograft or PRF clots.

Material And Methods: Thirty sinus lifts with simultaneous implantation were conducted using a lateral window approach and the tent pole technique, with xenograft (group 1 (G1)) or PRF (group 2 (G2)) as a filling material. To be included in the study, patients must have had an alveolar ridge height of 4-5 mm, no signs of inflammatory processes, good oral hygiene, and no other grafting procedures performed in region of implant insertion. In each case, the measurements taken were probing pocket depth (PPD), height of keratinized tissue (HKT), clinical attachment level (CAL), recession depth/width (RD/RW), and, on panoramic X-rays, marginal bone loss (MBL), grafted sinus high (GSH), and bone gain (BG). Preand post-operative treatment was applied to reduce the chance of infection.

Results: During the study, 30 implants (hydroxyapatite-coated implants manufactured by SGS - 10 mm in length and 4.2 mm in diameter) were placed. The survival rate of implants in both groups was 100% with no implant mobility, pain, paresthesia, or inflammatory processes in the direct vicinity of the implants observed, except in 1 patient. After 36 months of follow-up, the radiological assessments for G1 were: GSH 4.5 mm, MBL 0.46 mm and BG 4.53 mm; and for G2: 3.4 mm, 0.6 mm and 3.4 mm, respectively. Results of the clinical measurements were for G1: HKT after 36 months (HKT36) 2.46 mm, CAL 0.47 mm and PPD 2 mm; and for G2: HKT36 3.13 mm, CAL 0.6 mm and PPD 2.07 mm.

Conclusions: After 3 years of follow-up, the results of sinus lifting solely using PRF with simultaneous implantation were promising, especially in terms of soft tissue management. Therefore, PRF can be regarded as an alternative to previously used materials.

Download full-text PDF

Source
http://dx.doi.org/10.17219/acem/134202DOI Listing

Publication Analysis

Top Keywords

implant placement
8
sinus lift
8
simultaneous implantation
8
inflammatory processes
8
prf
6
sinus
6
prf versus
4
versus xenograft
4
xenograft sinus
4
sinus augmentation
4

Similar Publications

Introduction: Soft-tissue defect is commonly seen in immediate maxillary posterior implantation because of tooth extraction wound and tension from bone graft. Bone graft materials exposure has a significant detrimental influence on bone augmentation. However, previous studies lack sufficient evidence to guide wound closure after immediate posterior implantation.

View Article and Find Full Text PDF

Purpose: A finite element analysis was performed to simulate the biomechanical differences between anterior-posterior (AP) direction and posterior-anterior (PA) direction placement of two cannulated screws in Hoffa fractures.

Methods: Computed tomography images of an healthy male volunteer were used to simulate Letenneur Ⅰ, Ⅱa, Ⅱb, Ⅱc, Ⅲ Hoffa fractures, and two groups of screw internal fixation models were constructed. Two 6.

View Article and Find Full Text PDF

Purpose: Cochlear implantation (CI) surgery is essential for restoring hearing in individuals with severe sensorineural hearing loss. Accurate placement of the electrode within the cochlea is essential for successful auditory outcomes and minimizing complications. This study aims to analyze the relationship between the round window niche (RWN) alignment, its visibility during surgery, and the impact on surgical techniques and outcomes.

View Article and Find Full Text PDF

Statement Of Problem: Although immediate implant loading has shown promising clinical results and high survival rates, an increased risk of implant failure and complications has been reported. Achieving consistently predictable outcomes with this approach remains a challenge, but evidence-based guidelines to assist in selecting suitable patients are lacking.

Purpose: The purpose of this retrospective clinical study was to investigate the success rate, survival rate, and complications of immediate implant loading compared with early and delayed loading.

View Article and Find Full Text PDF

Objective: Intraventricular baclofen (IVB) administration is used for the treatment of secondary dystonia associated with cerebral palsy (CP), but it has not been reported as a first-line infusion technique for spasticity. In this study, the authors report outcomes of patients with mixed or isolated spasticity treated with IVB administration.

Methods: A retrospective analysis was performed of consecutive patients treated with IVB between 2019 and 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!