The reciprocate scanning scheme of two-dimensional galvanometers is widely used in laser confocal scanning microscopes with high speed. However, the equal interval acquisition of an analog digital acquisition card (AD) and the unequal change of the galvanometer's scanning speed will cause the dislocation of pixels and distortion of the reconstructed image. Meanwhile, the movement properties of the galvanometers in the edge of the scanning area are complex, which will increase the difficulty of segmenting the collected one-dimensional data stream the AD collected into row data of a two-dimensional reconstructed image. Therefore, how to timely and accurately segment the one-dimensional data stream the AD collected into the row data of two-dimensional reconstructed image is not only the key to solve image distortion of a laser confocal scanning microscope with high speed but also the prerequisite to improve the accuracy of row data dislocation correction. A driving mode based on the nonlinear triangular wave and a dislocation-correcting method using a square wave index are proposed. Namely, on the basis of the galvanometer's scanning analysis, the equation of a nonlinear triangular wave driving voltage is established, and the switching frequency of the Y-galvanometer's driving voltage is obtained by calculating the collected switching frequency of the X-galvanometer; thus, the uniformity of the galvanometer's scanning trajectories is secured. Finally, the row segmentation flag pulse is first introduced into the one-dimensional data stream the AD collected, and the square wave index is used to segment the collected data, which means the one-dimensional data stream can be segmented timely and accurately via hardware method. Meanwhile, the pixel dislocation can be corrected. The experimental result shows that, compared with the Nikon A1R+ confocal microscope, the proposed method can effectively correct the pixel dislocation, and the position coincidence error is less than 0.7%. The proposed method will be helpful to improve the image quality of a laser confocal scanning microscope with high speed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.420889 | DOI Listing |
Rev Sci Instrum
January 2025
Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, 14109 Berlin, Germany.
Confocal microscopy is an invaluable tool for studying fluorescent materials and finds a wide application in biology and in quantum sensing. Usually, these experiments are performed under ambient conditions, but many materials are air sensitive (for example, black phosphorus) and degrade quickly under the strong laser irradiance. Here, we present a glovebox-integrated confocal microscope designed for nitrogen-vacancy (NV) center-based nano-scale sensing and NMR spectroscopy in an inert gas atmosphere.
View Article and Find Full Text PDFFront Nutr
January 2025
College of Food Science, Northeast Agricultural University, Harbin, Heilongjiang, China.
Introduction: Frozen pork can reduce the quality of the meat and alter the digestibility and bioavailability of meat proteins in the human body. In this study, we investigated the changes in the basic composition during frozen storage and their effects on the structural properties of digestion products after protein digestion.
Methods: The impacts of frozen storage at different temperatures (-8, -18, -25, and -40°C) and for different times (1, 3, 6, 9, and 12 months) on the basic components and digestive characteristics of pork were evaluated.
Biofilm
June 2025
Department of Infectious Diseases and Clinical Microbiology, Beijing Institute of Respiratory Medicine and Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China.
The biofilm formation of , a major human fungal pathogen, represents a crucial virulence factor during candidiasis. Eicosapentaenoic acid (EPA), a polyunsaturated fatty acid, has emerged as a potential antibiofilm agent against . .
View Article and Find Full Text PDFObjective This in vitro study aimed to assess and compare the antimicrobial effectiveness of ampicillin with ceftriaxone (AC), diclofenac sodium (DS), modified triple antibiotic paste (MTAP), and calcium hydroxide (CH) against in root canal systems. Materials and methods The antimicrobial activity of the medicaments was assessed by determining the minimum inhibitory concentrations (MIC) via the agar well diffusion method. A total of 40 extracted permanent teeth underwent root canal treatment, and was introduced into the canal preparations.
View Article and Find Full Text PDFHeliyon
January 2025
Key Laboratory of Molecular Biology for Infectious Diseases (Ministry of Education), Institute for Viral Hepatitis, Department of Infectious Diseases, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China.
Background: () is one of the most common pathogens associated with deep fungal infection, which represents a serious threat to human health. Although high mobility group box 1 (HMGB1) plays a key role in infection, its mechanism is unclear. We aimed to explore the regulation of small-molecule non-coding RNA (miRNA) for HMGB1 in infection.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!