We evaluated the angiographic parameter and clinical outcomes of drug-coated balloon (DCB) to assess the optimal angiographic criteria in de novo small vessel disease (SVD). Patients (n = 424, mean age: 64.4 ± 11.2 years, men: 69.8%) at 20 sites in Korea were prospectively enrolled. The primary end point was late luminal loss (LLL) at 9-month follow-up angiography. Secondary end points included restenosis rates, target lesion failure (TLF), and DCB-related thrombosis during the 12-month follow-up period. We included 403 patients for analysis excluding 21 patients who required bailout stenting. Baseline mean reference vessel .diameter was 2.52 ± 0.39 mm and mean minimal luminal diameter (MLD) was 0.71 ± 0.40 mm. The mean MLD was 1.54 ± 0.37 mm after DCB. Late luminal loss was -0.01 ± 0.43 mm and restenosis was noted in 26 patients (12.2%). Minimal luminal diameter >1.6 mm and %DS <45% after DCB was associated maintenance of MLD without LLL at 9-months. Multivariate analysis demonstrated that %DS at baseline and post-MLD was associated with the restenosis. During 12-month follow-up, TLF was 2.6% including 1 cardiac death, 1 myocardial infarction, and 10 ischemia-driven target lesion revascularizations. Drug-coated balloon showed a low restenosis and lower LLL despite high in-segment DS. Post-MLD and % DS may be helpful to get optimal results in de novo SVD after DCB.

Download full-text PDF

Source
http://dx.doi.org/10.1177/00033197211015534DOI Listing

Publication Analysis

Top Keywords

outcomes drug-coated
8
drug-coated balloon
8
novo small
8
small vessel
8
late luminal
8
luminal loss
8
minimal luminal
8
luminal diameter
8
predictors favorable
4
favorable angiographic
4

Similar Publications

Endovascular treatment of femoropopliteal artery (FPA) disease with Drug-coated balloons (DCBs) may face complications such as arterial recoil, dissection, and residual stenosis. Angiography has limited accuracy for evaluating blood flow through revascularized target lesions. Thus, there is a need for post-procedure hemodynamic assessment in treated limbs.

View Article and Find Full Text PDF

Background: Drug-coated balloons present a potentially advantageous therapeutic approach for managing coronary in-stent restenosis (ISR). However, the comparative benefits of paclitaxel-coated balloons (PCBs) over uncoated balloons (UCBs) remain unclear.

Aims: We conducted a systematic review and meta-analysis to evaluate and compare the clinical outcomes of patients treated with PCBs and UCBs.

View Article and Find Full Text PDF

Background: Left main coronary bifurcation lesions account for 50% of left main coronary artery disease cases. Although a drug-coated balloon (DCB) has the advantages of immediate release of the drug to the arterial wall and no remaining struts, there is no conclusive evidence to support DCB use.

Methods & Results: We conducted a systematic review in compliance with the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) statement.

View Article and Find Full Text PDF

Background: Few studies investigated the implications of post-PCI QFR and post-PCI ΔQFR (absolute increase of QFR) in de novo lesions of small coronary disease after drug-coated balloon (DCB).

Objectives: We sought to investigate the prognostic implications of post-PCI QFR and post-PCI ΔQFR in patients who received DCB only.

Methods: Patients were divided according to the optimal cutoff value of the post-PCI QFR and the post-PCI ΔQFR.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!