An 82-year-old man underwent total aortic arch replacement with a 24 mm Triplex four-branched graft for aortic arch aneurysm. After two years, he was diagnosed with pseudoaneurysms due to bleeding from a non-anastomotic site of the branch graft to the left common carotid artery and minor leakage from a distal anastomotic site of the main graft. A self-expandable Fluency covered stent and cTAG thoracic endograft were used for the aneurysm. After four years, he was referred to our hospital with a complaint of pulsatile swelling of the anterior chest wall. Contrast enhanced computed tomography (CT) revealed a pseudoaneurysm arising from a non-anastomotic site of the branch graft to the left common carotid artery, which extended into the anterior chest wall and the skin through the sternum. He underwent emergency endovascular repair using a Niti-S ComVi covered stent. The postoperative course was uneventful. Postoperative CT showed shrinkage of the pseudoaneurysm. The patient was discharged and required no reintervention during the follow-up.
Download full-text PDF |
Source |
---|
A A Pract
January 2025
Department of Anesthesiology, University of Kansas Medical Center, Kansas City, Kansas.
Transcatheter aortic valve replacement (TAVR) is a common treatment for severe aortic stenosis (AS), but it carries the risk of severe complications, including device embolization. We present a case of a TAVR valve embolization into the left ventricular outflow tract (LVOT), diagnosed with transesophageal echocardiography (TEE) shortly after device deployment. The dislodged valve was successfully retrieved from the LVOT into the aorta, flattened, and stabilized with a thoracic endovascular aneurysm repair (TEVAR) stent, enabling the successful implantation of a new TAVR valve.
View Article and Find Full Text PDFArterioscler Thromb Vasc Biol
January 2025
Division of Cardiology, Department of Medicine, University of Washington (S.S., S.J., N.S., C.Y.L., L.L., D.A.D.).
Background: Smooth muscle cells (SMCs) of the proximal thoracic aorta are derived from second heart field (SHF) and cardiac neural crest lineages. Recent studies, both in vitro and in vivo, have implied relevance of lineage-specific SMC functions in the pathophysiology of thoracic aortic diseases; however, whether 2 lineage-derived SMCs have any predisposed transcriptional differences in the control aorta remains unexplored.
Methods: Single-cell RNA sequencing and single-nucleus assay for transposase-accessible chromatin sequencing were performed on isolated cells from the aortic root and ascending aortas of 14-week-old SHF-traced () and cardiac neural crest-traced () male mice.
Front Pharmacol
December 2024
Department of Clinical Pharmacy, Weifang People's Hospital, Shandong Second Medical University, Weifang, China.
Background: Recombinant human granulocyte-colony stimulating factors (G-CSF)-induced aortitis is a rare but particularly serious adverse event, commonly seen in cancer patients undergoing chemotherapy. The aim of this article is to clarify the clinical characteristics of G-CSF- induced aortitis and provide effective references for clinical diagnosis and intervention.
Methods: Case reports of adverse reactions of aortitis induced by G-CSF were collected from the relevant databases.
Semin Thorac Cardiovasc Surg
December 2024
Division of Cardiovascular and Thoracic Surgery, UTMB-Galveston, Galveston, TX. Electronic address:
Proximal control of the thoracic aorta during the open repair of thoracoabdominal aorta can be challenging. Various techniques have been developed to address these challenges, including the use of deep hypothermic circulatory arrest and staged procedures such as the conventional as well as frozen elephant trunk procedures. This paper is a brief review of the challenges and rationale behind some approaches.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!