A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sufentanil EC50 for endotracheal intubation with aerosol inhalation of carbonated lidocaine by ultrasonic atomizer. | LitMetric

Sufentanil EC50 for endotracheal intubation with aerosol inhalation of carbonated lidocaine by ultrasonic atomizer.

BMC Anesthesiol

Department of Anesthesiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1095 Jie Fang Avenue, Wuhan, 430030, Hubei, China.

Published: May 2021

Background: Nebulized lidocaine reduced stress response for endotracheal intubation. However, the impact of novel lidocaine aerosol inhalation for intubation by ultrasonic atomizer was unclear. Hence, we designed aerosol inhalation of lidocaine by ultrasonic atomizer, to seek whether the dosage of sufentanil for intubation could be less or not.

Methods: Intravenous injection of sufentanil started at 0.5 μg/kg, and sufentanil dosage was increased/decreased (step-size 0.05 μg/kg for sufentanil) using Dixon's up and down method. The observation was terminated after 8 reflexes.

Results: The EC50 and EC95 of sufentanil with lidocaine by ultrasonic atomizer for intubation were found to be 0.232 μg/kg (95% CI: 0.187-0.270 μg/kg) and 0.447 μg/kg (95% CI: 0.364-0.703 μg/kg). 55.88% out of 34 patients showed hemodynamic index change < 20% of baseline during intubation.

Conclusion: Aerosol inhalation of lidocaine by ultrasonic atomizer reduced the dosage of sufentanil for endotracheal intubation. Lidocaine inhalation by ultrasonic atomizer for airway anesthesia with minimal dosage of sufentanil could be recommended, particularly in patients who need more stable hemodynamic changes or spontaneous respiration.

Trial Registration: Chinese Registry of Central Trial, ChiCTR-IOR-17014198 . Registered 28 December 2017.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8114505PMC
http://dx.doi.org/10.1186/s12871-021-01367-wDOI Listing

Publication Analysis

Top Keywords

ultrasonic atomizer
16
aerosol inhalation
12
lidocaine ultrasonic
12
endotracheal intubation
8
sufentanil
6
intubation
5
lidocaine
5
sufentanil ec50
4
ec50 endotracheal
4
intubation aerosol
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!