Background: Difficulty in cannulation of arteriovenous fistula (AVF) can lead to inadequate dialysis, transient to permanent loss of access and increases dependency on bridging catheters. This study aimed to analyze the causes for difficult fistula cannulation, using various imaging modalities.

Methodology: This was a retrospective single-center observational study conducted between October 2017 and June 2018. Patients whose fistulae were difficult to cannulate were initially evaluated by physical examination followed by doppler ultrasonography or/and fistulogram as necessary. The patients were divided into two groups that is, primary difficult cannulation (within first three months of creation of fistula) or secondary difficult cannulation (after three months).

Results: We encountered difficult cannulation in 43 patients. About 60% were primary difficult cannulations. Most common causes for difficulty in cannulation were cannulation zone (CZ) stenosis (23.3%), immature fistula (20.9%), outflow stenosis (18.6%), inflow stenosis (11.6%), anatomical abnormalities (11.6%), outflow plus CZ stenosis (9.3%) and inflow plus CZ stenosis (4.7%). Among patients with primary difficult cannulation, immature fistula (34.6%) was the most common cause, whereas CZ stenosis (47.1%) was the most common etiology for secondary difficult cannulation. Edema leading to difficult cannulation was found in 12 patients (27.9%), all of which was due to central vein stenosis. Cannulation resulted in hematoma, fistula thrombosis, failure of fistula and pseudoaneurysm in 83.7%, 27.9%, 16.3%, and 2.3% of cases respectively. Bridging temporary dialysis catheter placement was required in 67.4% patients. Ultrasound doppler had lower diagnostic value when compared to fistulogram (71.4% vs 93.9%,  = 0.014).

Conclusion: Difficulty in cannulating the arteriovenous fistula is a common problem in hemodialysis patients. We suggest that patients whose fistulae are difficult to cannulate should undergo early radiological evaluation to decrease catheter dependency and access failure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7615862PMC
http://dx.doi.org/10.1177/11297298211015097DOI Listing

Publication Analysis

Top Keywords

difficult cannulation
28
arteriovenous fistula
12
primary difficult
12
difficult
11
cannulation
11
fistula
9
difficulty cannulation
8
patients
8
patients fistulae
8
fistulae difficult
8

Similar Publications

Background: Timely vascular access forms a necessary part of patient management in the Emergency Department (ED). Factors such as hypotension, intravenous drug use, obesity, dark skin, patients at extremes of age, and patients with multiple injuries may make peripheral intravenous cannulation difficult. The intraosseous route remains a suitable alternative for emergency circulatory access.

View Article and Find Full Text PDF

Background: Spinal cord injury (SCI) often leads to the loss of urinary sensation, making urination difficult. In a previous experiment involving six healthy participants, we measured heartbeat-induced acoustic pulse waves (HAPWs) at the mid-back, calculated time-series power spectra of heart rate gradients at three ultralow/very low frequencies, distinguished and formulated waveform characteristics (one characteristic for each power spectrum, nearly uniform across participants) at times of increased urine in the bladder and heightened urges to urinate, and developed an algorithm with five of these power spectra to identify when urination is needed by extracting the waveform portion (continuous timepoints) where all of the characteristics were consistent with the formulated characteristics. The objective of this study was to verify the validity of the algorithm fed with data from measured HAPW of participants with SCI and to adapt the algorithm for these individuals.

View Article and Find Full Text PDF

Background: More than 65% of patients with end-stage renal disease (ESRD) use arteriovenous fistulas (AVFs) for hemodialysis. The increasing incidence of comorbid ESRD and obesity (body mass index, >35 kg/m) precludes patients from kidney transplantation, resulting in a need for long-term, durable AVF access. Compared with traditional superficialization techniques for overlying adiposity, liposuction is minimally invasive and well-tolerated, allowing for earlier fistula use with lower complications.

View Article and Find Full Text PDF

Inserting a VA-ECMO cannula through an inferior vena cava filter during extracorporeal cardiopulmonary resuscitation.

Int J Emerg Med

December 2024

Department of Critical Care Medicine, Zhongda Hospital, Southeast University, No.87, Dingjiaqiao, Gulou District, Nanjing, 210009, China.

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) has been utilized to treat massive pulmonary embolism (PE) accompanied by cardiac arrest or refractory cardiogenic shock. Our team opted for a femoral-femoral approach for vascular cannulation, using drainage and return cannulas in the common femoral vein and artery, respectively. However, femoral venous cannulation can be limited or challenging due to the presence of thrombus in the inferior vena cava (IVC), making the insertion of the drainage cannula via the femoral vein difficult.

View Article and Find Full Text PDF

Background And Aims: Pancreatitis is the most common serious adverse event associated with endoscopic retrograde cholangiopancreatography (ERCP). This meta-analysis aimed to precisely assess the risk factors for post-ERCP pancreatitis (PEP).

Methods: We searched electronic databases for studies that assessed risk factors for PEP after adjusting for ≥3 risk factors, including at least one pre-specified patient-related and one procedure-related risk factor, and reported the data as adjusted odds ratios (OR) with 95% confidence intervals.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!