Background: Laparoscopic cholecystectomy (LCC) carries a 0.3-1.8% risk of bile duct injury (BDI). This study investigated if intraoperative photo documentation of the critical view of safety (CVS) is related to lower rates of BDIs and postoperative complications in LCC.

Methods: Surgeons were instructed to take photos of the view before clipping the cystic duct and artery. Two independent raters scored the photos 0-6 using predefined criteria for CVS. Mean scores of ≥4.5 were satisfactory.

Results: The study consisted of 1532 patients undergoing LCC between April 2018 and October 2019. CVS was satisfactory in 354 (23.1%), unsatisfactory in 823 (53.7%), and photos were missing in 355 (23.2%) patients. Patients with satisfactory CVS had the lowest BDI rate compared with unsatisfactory CVS or missing photos (0.3% vs. 1.0% vs. 2.3%, p = 0.012). Four major BDIs (Strasberg D-E) occurred, but none in patients with satisfactory CVS. Patients with satisfactory CVS had the lowest postoperative complication rate compared with patients with unsatisfactory CVS or without photos (4.8% vs. 7.9 vs. 9.9%, p = 0.011). Of patients with acute cholecystitis, 15.7% had satisfactory CVS, whereas 26.8% without cholecystitis had satisfactory CVS (p < 0.001).

Conclusion: Intraoperative photo documentation of satisfactory CVS is associated with lower rates of BDIs and complications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hpb.2021.04.017DOI Listing

Publication Analysis

Top Keywords

satisfactory cvs
20
patients satisfactory
12
cvs
10
critical view
8
view safety
8
bile duct
8
laparoscopic cholecystectomy
8
patients
8
1532 patients
8
cvs lowest
8

Similar Publications

Objectives: To describe the use of a three-dimensional-printed patient-specific guide system for the treatment of distal tibial varus deformity in Dachshunds and retrospectively report the clinical and radiographic outcome.

Materials And Methods: Pes varus deformity in nine limbs of seven dachshunds was treated with corrective osteotomy using a three-dimensional-printed patient-specific guide system. Data from computed tomography were processed to obtain virtual 3D-models of the tibias, which were used for computer-aided design-based surgical planning, three-dimensional-printed patient-specific guide system design and evaluation of planned versus achieved tibial correction.

View Article and Find Full Text PDF

Insight into the status of plasma renin and aldosterone measurement: findings from 526 clinical laboratories in China.

Clin Chem Lab Med

October 2024

12501 National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/ National Center of Gerontology, Beijing, P.R. China.

Objectives: Accurate measurements of renin and aldosterone levels play an important role in primary aldosteronism screening, which is of great importance in the management and categorization of hypertension. The objective of this study is to investigate the current status of plasma renin and aldosterone measurements in China, which is achieved by analyzing the results of 526 clinical laboratories nationwide for three pooled fresh plasma samples derived from more than 2,000 patients.

Methods: Renin and aldosterone in three pooled plasma samples were measured four times in 526 laboratories employing various measurement systems.

View Article and Find Full Text PDF

Background: The purpose of this study is to evaluate the performance of recently developed tumor marker clinical kits in China, with the aim of encouraging local medical technology innovation and thus narrowing the research and development gap with foreign kits.

Methods: The newly established reagent kits were analyzed on the TESMI F3999-Luminex200 flow lattice instrument to verify precision, sensitivity (blank limit), linearity, anti-interference ability, carry-over contamination rate, hook effect, and reference interval verification. Additionally, the newly established reagent kits were compared to other commercially available detection kits (reference reagent kits) to analyze the correlation between the two types of kits.

View Article and Find Full Text PDF

The use of thoracic endovascular aortic repair (TEVAR) for thoracic aortic aneurysm (TAA) and Stanford type B aortic dissection (TBAD) has been increasing; however, in terms of etiology, the differences of long term after TEVAR outcomes remain unexplored. Thus, we investigated etiology-specific long-term results of TEVAR for TAA and TBAD. A total of 421 TEVAR procedures were performed at our institution from July 2007 to December 2021; 249 TAA cases and 172 TBAD cases were included.

View Article and Find Full Text PDF

Purpose: This study aimed to translate and validate a Chinese version of the Comprehensive assessment of Acceptance and Commitment Therapy processes (CompACT-C), a 23-item questionnaire for measuring an individual's level of psychological flexibility among Chinese breast cancer survivors for utilisation of Acceptance and commitment therapy (ACT)-based interventions in breast cancer patients.

Methods: Six translators translated the original English version into Chinese according to Brislin's Translation Model. Psychometric properties tests were conducted on the CompACT-C, including internal consistency, test-retest reliability (two-week interval), face validity, content validity, convergent validity with experiential avoidance, and construct validity (confirmatory factor analysis).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!