Background: Given the prevalence of breast augmentation and prosthetic-based breast reconstruction, it is common for the plastic surgeon to see patients presenting for revisional implant surgery. A frequent issue encountered in such procedures is uncertainty of implant size, which presents numerous challenges and may lead to undesired outcomes for both the patient and the surgeon. There is currently no tool available with the purpose of measuring implant volume from magnetic resonance imaging (MRI) data. In this study, such a program was designed and tested.

Methods: An open-source software was developed that provides volume measurement of a chosen breast implant with minimal interaction from the user, allowing for precision in the planning of breast implant revisional surgery. It was developed to be as easy to use as possible for clinicians who may not have experience with imaging analysis platforms. The program was tested on patients who underwent revisional implant surgery and had documented implant volumes and pre-operative breast MRIs. Twenty-two implants were tested in total, including saline and both smooth and textured silicone implants.

Results: The software has shown to be highly accurate with an average accuracy of 98.6%. A Spearman correlation coefficient of 0.967 was obtained. The software also performed faster than previously proposed methods.

Conclusion: Plastic surgeons can easily calculate breast implant volume pre-operatively using BreastImplantAnalyzer, which is available to download for free from www.BreastImplantAnalyzer.com or as an extension for the popular medical imaging platform 3D Slicer.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bjps.2021.03.068DOI Listing

Publication Analysis

Top Keywords

breast implant
16
implant volume
12
implant
9
mri data
8
revisional implant
8
implant surgery
8
breast
7
breastimplantanalyzer easy-to-use
4
easy-to-use validated
4
validated tool
4

Similar Publications

Background: Nipple-sparing mastectomy (NSM) is infrequently performed in older women, at least in part owing to concerns regarding age-related complications. We describe postoperative outcomes of NSM in older women and risk factors for complications, with the goal of informing patient selection and decision-making.

Patients And Methods: Cases of NSM with immediate implant-based reconstruction were identified from an institutional database (2009-2019).

View Article and Find Full Text PDF

The (In-)Ability to Effectively Critique a Method Undermines the Validity of the Criticism.

Aesthetic Plast Surg

January 2025

Directorate General of Medical Devices and Pharmaceutical service of the Italian Ministry of Health, Via Ribotta 5, 00144, Rome, Italy.

Level of Evidence III This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors  www.springer.

View Article and Find Full Text PDF

Background: Breast implants interfere with myocardial perfusion imaging (SPECT) and echocardiographic windows leading to increased false positive results. To validate this concept, we hypothesized that patients with breast implants should have higher positive cardiac testing and coronary angiogram with lower percutaneous coronary intervention (PCI) rates compared to women without a breast implant.

Methods: Using ICD 10 codes for breast implants, abnormal results of cardiac functional study, coronary angiogram, and percutaneous coronary interventions, we evaluated any association between these parameters in adult women with breast implants utilizing the National Inpatient Sample (NIS) database.

View Article and Find Full Text PDF

Purpose: The aim of this study was to investigate the radiobiological effects underlying the inhibition of breast cancer (BCa) following radiotherapy in nude mice models, and to evaluate the impact of changes in immunohistochemical parameters induced by FF and FFF beams.

Materials And Methods: The study included thirty-six adult nude mouse models, which were randomly assigned to five groups: control (G1), breast cancer (BCa) (G2), FF-400 MU/min (G3), FFF-1100 MU/min (G4), and FFF-1800 MU/min (G5). The control group received neither radiation nor treatment, while the BCa group had a cancer model without radiation.

View Article and Find Full Text PDF

Time to reconsider the use of synthetic mesh in immediate prepectoral implant-based breast reconstruction: Impact of their use on short-term outcomes.

Eur J Surg Oncol

December 2024

Department of Surgical Oncology, Université de Caen Normandie, François Baclesse Centre, 3 avenue Général Harris, 14000, Caen, France. Electronic address:

Background: Breast reconstruction practices, predominantly implant-based, have evolved, with meshes aiding in overcoming traditional limitations. However, data comparing mesh-assisted prepectoral reconstruction with implants alone are lacking. This study aimed to assess whether synthetic meshes in prepectoral reconstruction impact postoperative complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!