A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

False lumen enhancement characteristics on computed tomography angiography predict risk of aneurysm formation in acute type B aortic dissection. | LitMetric

Objectives: Differential luminal enhancement [between true lumen (TL) and false lumen (FL)] results from differential flow patterns, most likely due to outflow restriction in the FL. We aimed to assess the impact of differential luminal enhancement at baseline computed tomography angiography on the risk of adverse events in patients with acute type B aortic dissection (TBAD).

Methods: Baseline computed tomography angiographies of patients with acute TBAD between 2007 and 2016 (n = 48) were analysed using three-dimensional software at multiple sites along the descending thoraco-abdominal aorta. At each location, we measured contrast density in TL and FL [Houndsfield unit (HU)], maximal diameter (cm) and circumferential FL extent (°). Outcome data were collected via retrospective chart review. Multivariable logistic regression models were employed to determine the independent risk of TL-FL differential luminal enhancement on aneurysm formation (maximal diameter ≥55 mm) and medical treatment failure.

Results: Patients were predominately male (75%) and 52.8±12.9 years at diagnosis. The mean follow-up was 5.9±2.6 years, and 42% (n = 20/48) patients were diagnosed with thoraco-abdominal aortic aneurysm. The baseline absolute difference between FL and TL contrast density measured at 2 cm distal to primary entry tear (TL-FLabs-Tear) was significantly higher among patients who developed aneurysm (26 HU, IQR: 15-53 vs 13 HU, IQR: 4-24, P = 0.001). Aneurysm development during follow-up was predicted by TL-FLabs-Tear (odds ratio 1.07, P = 0.012) and baseline maximal aortic diameter (odds ratio 1.90, P < 0.001). High (≥18 HU) differential luminal enhancement was associated with lower rates of aneurysm-free survival and higher rates of medical treatment failure.

Conclusions: Differential luminal enhancement may be a novel predictor of aneurysm formation among patients with acute TBAD.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8385453PMC
http://dx.doi.org/10.1093/icvts/ivab095DOI Listing

Publication Analysis

Top Keywords

computed tomography
12
differential luminal
12
luminal enhancement
12
false lumen
8
tomography angiography
8
aneurysm formation
8
acute type
8
type aortic
8
aortic dissection
8
baseline computed
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!