Cooling Nanorotors by Elliptic Coherent Scattering.

Phys Rev Lett

Faculty of Physics, University of Duisburg-Essen, Lotharstraße 1, 47048 Duisburg, Germany.

Published: April 2021

Simultaneously cooling the rotational and translational motion of nanoscale dielectrics into the quantum regime is an open task of great importance for sensing applications and quantum superposition tests. Here, we show that the six-dimensional ground state can be reached by coherent-scattering cooling with an elliptically polarized and shaped optical tweezer. We determine the cooling rates and steady-state occupations in a realistic setup and discuss applications for mechanical sensing and fundamental experiments.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevLett.126.163603DOI Listing

Publication Analysis

Top Keywords

cooling
4
cooling nanorotors
4
nanorotors elliptic
4
elliptic coherent
4
coherent scattering
4
scattering simultaneously
4
simultaneously cooling
4
cooling rotational
4
rotational translational
4
translational motion
4

Similar Publications

The Rift Valley fever virus (RVFV) causes haemorrhagic fever, encephalitis, and permanent blindness and has been listed by the WHO as a priority pathogen. To study RVFV pathogenesis and identify small-molecule antivirals, we established a novel In Vivo model using zebrafish larvae. Pericardial injection of RVFV resulted in ~4 log viral RNA copies/larva, which was inhibited by the antiviral 2'-fluoro-2'-deoxycytidine.

View Article and Find Full Text PDF

Direct Hot Solid-Liquid Extraction (DH-SLE): A High-Yield Greener Technique for Lipid Recovery from Coffee Beans.

Plants (Basel)

January 2025

Departamento de Química, Universidade Federal de Viçosa, Campus Universitário, Avenida Peter Henry Rolfs, s/n, Viçosa 36570-900, MG, Brazil.

Soxhlet extraction is a method recommended by the Association of Official Analytical Chemists (AOAC) to determine the lipid content in plant samples. Generally, n-hexane (toxicity grade 5) is used as the solvent (≈300 mL; ≈30 g sample) at boiling temperatures (69 °C) for long times (≤16 h) under a chilled water reflux (≈90 L/h), proportionally aggravated by the number of repetitions and samples determined. In this sense, the technique is neither safe nor sustainable for the analyst or the environment.

View Article and Find Full Text PDF

The integration of electronics into textiles has gained considerable attention in recent years, due to the development and high demand of wearable and flexible electronics. One of the promising fields is healthcare, which often involves the utilization of textile-based electrodes. These electrodes often offer advantages such as conformability, breathability, and comfort.

View Article and Find Full Text PDF

: To compare tracheal temperature (T) with nasopharyngeal temperature (T) in patients undergoing cardiac surgery using cardiopulmonary bypass (CPB). : T was measured using a thermistor in the cuff of an endotracheal tube and T was monitored using an esophageal stethoscope. Depending on the management of the CPB strategy, the operation was divided into four periods (pre-CPB, cooling, rewarming, and post-CPB).

View Article and Find Full Text PDF

: Hypoxic-ischemic encephalopathy (HIE) in late preterm and term neonates accounts for neonatal mortality and unfavorable neurodevelopmental outcomes in survivors despite therapeutic hypothermia (TH) for neuroprotection. The circumstances of death in neonates with HIE, including involvement of neonatal palliative care (NPC) specialists and neurodevelopmental follow-up at 18-24 months in survivors, warrant further evaluation. : A retrospective multicenter cohort study including neonates ≥ 35 weeks gestational age with moderate to severe HIE receiving TH, registered in the Swiss National Asphyxia and Cooling Register between 2011 and 2021.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!