Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.rx.2021.04.002 | DOI Listing |
Cancer Imaging
January 2025
Melbourne Theranostic Innovation Centre, Level 8, 14-20 Blackwood St, North Melbourne, VIC, 3051, Australia.
True total-body and extended axial field-of-view (AFOV) PET/CT with 1m or more of body coverage are now commercially available and dramatically increase system sensitivity over conventional AFOV PET/CT. The Siemens Biograph Vision Quadra (Quadra), with an AFOV of 106cm, potentially allows use of significantly lower administered radiopharmaceuticals as well as reduced scan times. The aim of this study was to optimise acquisition protocols for routine clinical imaging with FDG on the Quadra the prioritisation of reduced activity given physical infrastructure constraints in our facility.
View Article and Find Full Text PDFBMC Med Imaging
January 2025
Department of Radiology, Huadong Hospital, Fudan University, Shanghai, 200040, China.
Background: Interstitial lung abnormalities (ILA) are a proposed imaging concept. Fibrous ILA have a higher risk of progression and death. Clinically, computed tomography (CT) examination is a frequently used and convenient method compared with pulmonary function tests.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Radiology, The First Hospital of China Medical University, Shenyang, Liaoning, PR China.
Much evidence suggests that the choroid plexus (CP) plays an important role in the pathophysiology of systemic lupus erythematosus (SLE), but its imaging profile in neuropsychiatric SLE (NPSLE) remains unexplored. To evaluate CP volume in NPSLE patients using MRI. This retrospective study evaluated patients with SLE who underwent MRI of the brain, including three-dimensional T1-weighted imaging.
View Article and Find Full Text PDFInsights Imaging
January 2025
Diagnostic and Interventional Radiology, University Hospital of Zurich, University Zurich, Zurich, Switzerland.
Objectives: To compare and correlate bone edema volume detected by 3D-short-tau-inversion-recovery (STIR) sequence to osseous decay detected by a T1-based sequence and conventional panoramic radiography (OPT).
Materials And Methods: Patients with clinical evidence of apical periodontitis were included retrospectively and received OPT as well as MRI of the viscerocranium including a 3D-STIR and a 3D-T1 gradient echo sequence. Bone edema was visualized using the 3D-STIR sequence and periapical hard tissue changes were evaluated using the 3D-T1 sequence.
Int Ophthalmol
January 2025
Department of Ophthalmology, Command Hospital, Pune, 411040, India.
Purpose: This study aimed to evaluate whether the digital eye strain (DES) was associated with the low central corneal thickness (CCT).
Methods: This observational cross-sectional pilot study was conducted from April 2023 to October 2023 at a tertiary eye care centre in North India, where CCT values were compared between subjects with DES and those without DES. Two hundred and eighty subjects (n = 280) aged 15-40 years with clear corneas and lenses were initially included in this study.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!