Magnetic Solid-Phase Extraction Based on Amino-functionalized Magnetic Starch for Analysis of Organochlorine Pesticides.

Anal Sci

Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, 40002, Thailand.

Published: November 2021

A magnetic starch modified with 3,5-diaminobenzoic acid and 3-aminopropyltriethoxysilane (Fe-starch@DABA-APTES) was synthesized and applied as adsorbent for the extraction of organochlorine pesticides (OCPs). Magnetic solid-phase extraction was developed using 75 mg of the sorbent and 15 mL of a sample solution. Extraction was conducted on a vortex mixer for 40 s. The adsorbent was collected using an external magnet before eluting the analytes using 0.5 mL of methanol. Quantification of the analytes was performed using gas chromatography with a micro-electron capture detector. The linearity was obtained for the studied OCPs in the range between 0.01 - 2.00 μg L. The detection and quantification limits were obtained in ranges of 0.5 - 4.0 and 1.5 - 15.0 ng L, respectively, with enrichment factors of up to 39. The precision in terms of the intra- and inter-day relative standard deviations (RSDs) were below 4.75, and 9.25%, respectively. The developed method has been applied in natural water and agricultural product samples. The recoveries ranged between 59.83 - 132.67% (RSDs < 10.73%).

Download full-text PDF

Source
http://dx.doi.org/10.2116/analsci.21P034DOI Listing

Publication Analysis

Top Keywords

magnetic solid-phase
8
solid-phase extraction
8
magnetic starch
8
organochlorine pesticides
8
magnetic
4
extraction
4
extraction based
4
based amino-functionalized
4
amino-functionalized magnetic
4
starch analysis
4

Similar Publications

An easy applicable and selective sample preparation technique has been developed for trace and simultaneously analysis of Glipizide (GLP) and Pravastatin (PST) molecules in biological matrices based on magnetic solid phase extraction (MSPE) and high-performance liquid chromatography (HPLC). A new magnetic adsorbent including FeO@TEOS-Melamine has been synthetized and characterized for extraction studies. Experimental variables of MSPE were examined and optimized step by step such as pH, adsorption and desorption conditions, time effect, etc.

View Article and Find Full Text PDF

Automated High-Throughput Affinity Capture-Mass Spectrometry Platform with Data-Independent Acquisition.

J Proteome Res

January 2025

Discovery Research, AbbVie, Inc., 1 North Waukegan Rd., North Chicago, Illinois 60064, United States.

Affinity capture (AC) combined with mass spectrometry (MS)-based proteomics is highly utilized throughout the drug discovery pipeline to determine small-molecule target selectivity and engagement. However, the tedious sample preparation steps and time-consuming MS acquisition process have limited its use in a high-throughput format. Here, we report an automated workflow employing biotinylated probes and streptavidin magnetic beads for small-molecule target enrichment in the 96-well plate format, ending with direct sampling from EvoSep Solid Phase Extraction tips for liquid chromatography (LC)-tandem mass spectrometry (MS/MS) analysis.

View Article and Find Full Text PDF

Synthesis of a fluorophilic magnetic microporous organic network for selective enrichment of fipronil and ethiprole in milk and egg samples.

J Chromatogr A

January 2025

State Key Laboratory of Advanced Drug Delivery and Release Systems, and Medical Science and Technology Innovation Center, School of Pharmaceutical Sciences & Institute of Materia Medica, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, Shandong 250117, China. Electronic address:

Considering the widespreadly use, large consumption, and serious environmental and health threats of phenylpyrazole insecticides (PPIs), development of a selective and sensitive method for accurate detection of their residuals in food samples is of great significance and challenging. Herein, depending on the hydrophobic and F-containing characteristics of PPIs, a novel fluorinated magnetic microporous organic network (FMMON) was designed and prepared for efficient and selective magnetic solid-phase extraction (MSPE) of two typical PPIs (fipronil and ethiprole) from milk and egg samples before the HPLC-UV determination. FMMON owned large specific surface area, multiple interaction sites, excellent magnetic separation performance and stability and exhibited good extraction and selectivity for fipronil and ethiprole through the specific F-F, hydrogen bonding, hydrophobic, and π-π interactions.

View Article and Find Full Text PDF

(PCV2) is the main and primary causative agent of Postweaning Multisystemic Wasting Syndrome (PMWS). To date, immunoperoxidase monolayer assay (IPMA), indirect immunofluorescent assay (IFA), and enzyme linked immunosorbent assay (ELISA) are the most commonly diagnostic methods for detecting PCV2 antigens. However, these methods require specialized equipment and technical expertise and are suitable for laboratory use only.

View Article and Find Full Text PDF

An on-site, sensitive, and cost-effective method for determining aflatoxin B1 (AFB1) in rice samples is proposed, combining magnetic solid phase extraction (MSPE) and time-resolved fluorescence immunochromatography (TRFICA) techniques. Cost-effective rice husks were carbonized and combined with nanomaterials to make magnetic nanocomposites that acted as effective adsorbents in MSPE. Under optimal conditions, the entire process was completed in 15 min with a visual detection limit of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!