Lateral lumbar interbody fusion procedures are performed with multimodality neuromonitoring of the femoral nerve to prevent lumbosacral plexus and peripheral nerve injury from positioning, dilation, retraction, and hardware implantation. The integrity of the femoral nerve can be continuously assessed during these procedures by Somatosensory Evoked Potentials of the Saphenous nerve (Sn-SSEPs). Sn-SSEPs are technically challenging to acquire and necessitate advanced troubleshooting skills with a more rigid anesthetic regimen and physiological parameters. We performed a retrospective analysis of Sn-SSEP data for 100 consecutive lateral lumbar surgeries where the stimulation electrodes were placed distally below the knee and medial to the tibia bone (i.e., DSn-SSEPs). Monitorable baseline responses were present in 87% of patients after the exclusion of fourteen cases where the tibial nerve SSEP was absent, quadriceps transcranial electrical motor evoked potentials (TCeMEPs) were absent or not utilized. Sex, age, body mass index (BMI), diagnosis, mean arterial pressure (MAP), inhalational anesthetic levels, reliability of ulnar and posterior tibial nerve SSEPs, and the reliability of femoral nerve innervated quadriceps TCeMEPs were evaluated but were not of statistically significant consequence between cases where the DSn-SSEP was present or absent in this study. We found the utilization of DSn-SSEPs to be a valuable adjunct to femoral nerve monitoring. Stimulation electrode placement is easy to palpate with clear anatomical borders. Significant muscle artifact and patient movement from stimulation do not affect waveform morphology, allowing for continuous and reliable monitoring. We recommend including DSn-SSEPs to optimize recordings during lateral lumbar procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1080/21646821.2021.1903277DOI Listing

Publication Analysis

Top Keywords

lateral lumbar
16
femoral nerve
16
evoked potentials
12
nerve
9
medial tibia
8
saphenous nerve
8
somatosensory evoked
8
tibial nerve
8
distal stimulation
4
stimulation site
4

Similar Publications

Article Synopsis
  • Cage subsidence can negatively affect lumbar fusion procedures, with material selection (PEEK vs. 3D-Ti) influencing this issue; the study aims to compare their subsidence rates.
  • The systematic search reviewed 265 patients from three high-quality studies, focusing on cage subsidence and classified subsidence rates using a specific method.
  • Results indicated that 3D-Ti cages have a significantly lower rate of subsidence compared to PEEK cages, with less severe subsidence and better overall performance.
View Article and Find Full Text PDF

Objective: In the current study, to demonstrate the advantages of oblique lateral interbody fusion (OLIF), we focused on the therapeutics for lumbar spinal tuberculosis with the comparison of three treatments, including anterior approach, posterior approach, and OLIF combined with posterior percutaneous pedicle screw fixation.

Methods: This study included patients with lumbar spinal tuberculosis from July 2015 to June 2018. We divided these patients into three groups: 35 patients underwent an anterior-only approach (Group A), 36 patients underwent a posterior-only approach (Group B), and 31 patients underwent OLIF combined with posterior percutaneous pedicle screw fixation (Group C).

View Article and Find Full Text PDF

As PI-LL mismatch is an effective index for spinal surgery and PI-LL less than 10 probably indicates better quality of life, this study aimed to assess spinopelvic parameters, lumbar instability, and lumbar muscle morphology in patients with chronic low back pain (CLBP) with different PI-LL mismatches. This cross-sectional study included 158 CLBP patients. The association between lumbar extensor muscle morphology (measured from magnetic resonance imaging) and spinopelvic parameters (measured from standing lateral radiographs) and lumbar instability (measured from lumbar flexion/extension radiographs) was compared between two groups of patients with different PI-LL mismatch.

View Article and Find Full Text PDF

Applying a three-dimensional curved lumbar spine model to simulate surgery for training residents in pedicle screw insertion.

Surg Radiol Anat

December 2024

Department of Anatomy, Digital Imaging and 3D Modelling Laboratory, Faculty of Medicine, Ege University, Bornova, 35100, Izmir, Turkey.

Purpose: The challenges of spinal surgery can be overcome by deeply understanding the anatomical and surgical complexities of the region through the use of model simulators. This study investigates the impact of digitally designed simulators, specifically lumbar spinal models with abnormal curvature, on preoperative planning and their effectiveness as training tools. The study addresses challenges in spine surgery, such as unique deformities, classification issues, and associated abdominal structure abnormalities.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!