In this paper a practical solution for the reconstruction and segmentation of low-contrast X-ray tomographic data of protein crystals from the long-wavelength macromolecular crystallography beamline I23 at Diamond Light Source is provided. The resulting segmented data will provide the path lengths through both diffracting and non-diffracting materials as basis for analytical absorption corrections for X-ray diffraction data taken in the same sample environment ahead of the tomography experiment. X-ray tomography data from protein crystals can be difficult to analyse due to very low or absent contrast between the different materials: the crystal, the sample holder and the surrounding mother liquor. The proposed data processing pipeline consists of two major sequential operations: model-based iterative reconstruction to improve contrast and minimize the influence of noise and artefacts, followed by segmentation. The segmentation aims to partition the reconstructed data into four phases: the crystal, mother liquor, loop and vacuum. In this study three different semi-automated segmentation methods are experimented with by using Gaussian mixture models, geodesic distance thresholding and a novel morphological method, RegionGrow, implemented specifically for the task. The complete reconstruction-segmentation pipeline is integrated into the MPI-based data analysis and reconstruction framework Savu, which is used to reduce computation time through parallelization across a computing cluster and makes the developed methods easily accessible.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8127374 | PMC |
http://dx.doi.org/10.1107/S1600577521003453 | DOI Listing |
Vet Radiol Ultrasound
January 2025
Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada.
A young, intact, female, American Bulldog was presented for hemorrhagic vaginal discharge. Anemia, thrombocytopenia, leukocytosis with neutrophilia, azotemia, and electrolyte disturbances were detected in the bloodwork. A urachal diverticulum with concurrent uterine distention was identified by ultrasonography and CT.
View Article and Find Full Text PDFAim: To evaluate characteristics of atherosclerotic plaques (ASP) remaining after percutaneous coronary intervention (PCI) in patients with acute coronary syndrome (ACS) by coronary computed tomography angiography (CCTA).
Material And Methods: Among 249 patients (193 men) with ACS aged 58±10 years, 183 (73.5%) had myocardial infarction, 66 (26.
Phys Med Biol
January 2025
Department of Radiology, University of Chicago, 5841 South Maryland Avenue, Chicago, IL 60637, USA, Chicago, 60637, UNITED STATES.
Objective: Accurate image reconstruction from data with truncation in X-ray computed tomography (CT) remains a topic of research interest; and the works reported previously in the literature focus largely on reconstructing an image only within the scanning field-of-view (FOV). We develop algorithms to invert the data model with truncation for accurate image reconstruction within the entire subject support or a region slightly smaller than the subject support.
Methods: We formulate image reconstruction from data with truncation as an optimization program, which includes hybrid constraints on image total variation (TV) and image L1-norm for effectively suppressing truncation artifacts.
PLoS One
January 2025
Department of Ophthalmology, Pennsylvania State University, Hershey, PA, United States of America.
Purpose: To investigate different measures for corneal astigmatism in the context of reconstructed corneal astigmatism (recCP) as required to correct the pseudophakic eye, and to derive prediction models to map measured corneal astigmatism to recCP.
Methods: Retrospective single centre study of 509 eyes of 509 cataract patients with monofocal (MX60P) IOL. Corneal power measured with the IOLMaster 700 keratometry (IOLMK), and Galilei G4 keratometry (GK), total corneal power (TCP2), and Alpin's integrated front (CorT) and total corneal power (CorTTP).
Phys Med Biol
January 2025
Capital Normal University, 105, North West Sanhuan Road, Haidian District, Beijing, Beijing, None Selected, 100048, CHINA.
Objective: Low-dose computed tomography (LDCT) has gained significant attention in hospitals and clinics as a popular imaging modality for reducing the risk of X-ray radiation. However, reconstructed LDCT images often suffer from undesired noise and artifacts, which can negatively impact diagnostic accuracy. This study aims to develop a novel approach to improve LDCT imaging performance.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!