Previous works from our laboratory have firmly established that aerogels are a suitable substrate to elicit accelerated neurite extension. On non-conducting aerogels, in the presence of an externally-applied DC bias, neurons extended neurites which were preferentially aligned towards the anode. In this investigation, we sought to determine whether electrically-conductive carbon aerogels elicited a more robust alignment of neurites toward the anode than non-conductive aerogels due to the capacity of conductive aerogels to sustain a current, thereby providing a direct interface between neurons and the external electrical stimulus. To determine if this was the case, we plated PC12 neuronal cells on electrically conductive carbon aerolges derived from acetic acid-catalized resorcinol formaldehyde aerogels (ARF-CA) and subjected them to an external electric field. The voltages applied at the electrodes of the custom-built electro-stimulation chamber were 0 V, 15 V, and 30 V. For each voltage, the directionality and length of the neurites extended by PC12 cells were determined and compared to those observed when PC12 cells were plated on non-conductive aerogels subjected to the same voltage. The results show that the directionality of neurite extension was similar between conductive and non-conductive aerogels. A higher neurite length difference was observed on conductive aerogels with increasing voltage, 43% and 106% for 0-15 V and 0-30 V respectively, compared to non-conductive aerogels, 12% and 20%. These findings indicate that conductive carbon aerogels have a greater potential as scaffolds for nerve regeneration than non-conductive ones.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d1sm00183cDOI Listing

Publication Analysis

Top Keywords

non-conductive aerogels
16
conductive carbon
12
aerogels
11
electrically conductive
8
external electric
8
electric field
8
neurite extension
8
carbon aerogels
8
conductive aerogels
8
voltage directionality
8

Similar Publications

Previous works from our laboratory have firmly established that aerogels are a suitable substrate to elicit accelerated neurite extension. On non-conducting aerogels, in the presence of an externally-applied DC bias, neurons extended neurites which were preferentially aligned towards the anode. In this investigation, we sought to determine whether electrically-conductive carbon aerogels elicited a more robust alignment of neurites toward the anode than non-conductive aerogels due to the capacity of conductive aerogels to sustain a current, thereby providing a direct interface between neurons and the external electrical stimulus.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!