Wrong Tissue in Block.

Am J Clin Pathol

Department of Pathology, Immunology and Laboratory Medicine, University of Florida College of Medicine, Gainesville, FL, USA.

Published: September 2021

AI Article Synopsis

  • * Initially, there were no block confirmations required, resulting in a certain number of WTIB incidents, but after implementing a mandatory confirmation process and a hard stop feature, the errors significantly decreased.
  • * The results showed an 88.4% reduction in WTIB incidents post-implementation, demonstrating the effectiveness of custom workflows and technology in improving specimen identity management in laboratories.

Article Abstract

Objectives: Maintaining specimen identity during surgical pathology tissue processing is critical. Epic Beaker Laboratory Information System requires sequential scanning of specimen label and grossed blocks (block confirmation) to ensure specimen identity. We report our institution's experience with wrong tissue in block (WTIB) grossing errors before and after adopting block confirmation.

Methods: During the first 18 months of Beaker implementation, block confirmation was not required. We then mandated block confirmation for a 3-month period. To ensure compliance, we then built a "hard stop" feature that prevents scanning any unconfirmed blocks onto a packing list. We reviewed WTIB incidents pre- and postimplementation of these solutions.

Results: Before using block confirmation, we had WTIB incidents involving 17 (0.043%) of 38,848 cases. When we mandated block confirmation use, we had WTIB involving 2 (0.043%) of 4,646 cases. After implementing the hard stop feature, we had WTIB incidents involving 2 (0.005%) of 42,411 cases. Overall, there was an 88.4% (0.043% vs 0.005%; P < .001) reduction in WTIB incidents using block confirmation with a hard stop.

Conclusions: Beaker is a customizable platform that can be tailored to a laboratory's workflow. By using barcoding, implementing custom-built features, and improving workflow protocols, we significantly reduced WTIB errors.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ajcp/aqab011DOI Listing

Publication Analysis

Top Keywords

block confirmation
24
wtib incidents
16
block
9
wrong tissue
8
tissue block
8
specimen identity
8
mandated block
8
confirmation wtib
8
incidents involving
8
involving 0043%
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!