A colorimetric sensor based on gold nanoparticles (AuNPs) and single-stranded DNA (ssDNA) is a simple and rapid method for detecting foodborne pathogens. However, the colorimetric method employed in previous studies involved short ssDNA (<100 nucleotides), including the aptamer and PCR products, resulting in the high detection limit of this technique. In this study, a colorimetric sensor was developed based on long ssDNA of asymmetric PCR (aPCR) and non-functionalized AuNPs for detecting Salmonella Typhimurium (S. Typhimurium). In the presence of S. Typhimurium, the long ssDNA (547 nt) amplified by aPCR-protected AuNPs from NaCl-induced aggregation, while the solution retained a red color. After optimizing parameters, the limit of detection (LOD) of the colorimetric sensor was 2.56 CFU/mL with high specificity. Recovery studies showed its feasibility for detecting S. Typhimurium (10 CFU/mL, 10 CFU/mL, and 10 CFU/mL) in spiked lettuce samples. This colorimetric sensor provides new opportunities for the highly sensitive detection of bacteria in real food samples.