Background: Our aim was to assess safety and efficacy outcomes at 1 year after MitraClip for percutaneous mitral valve repair in patients with severe mitral regurgitation. Twenty consecutive patients with significant MR (GIII or GIV) were selected according to the AHA/ACC guidelines from June 2016 to June 2019 and underwent percutaneous edge-to-edge mitral valve repair using MitraClip with a whole 1 year follow-up following the procedure. The primary acute safety endpoint was a 30-day freedom from any of the major adverse events (MAEs) or rehospitalization for heart failure. The primary efficacy endpoint was acute procedural success defined as clip implant with an improvement of MR to ≤ grade II, based on current guidelines, NYHA class, ejection fraction, and the left atrium size during follow-up.

Results: Mean age of the studied population was 66.8 ± 10 years and about 85% were males. All patients presented with NYHA > 2. EuroSCORE ranged between 7 and 15. Patients varied regarding their HAS-BLED score. None of them experienced MAEs at 30 days. Patients showed significant improvement of NHYA functional class, and all echocardiographic measurements such as left ventricular end systolic diameter, left ventricular end diastolic diameter, left ventricular ejection fraction, left atrium volume index and MR grade. They also showed significant improvement of right-side heart failure manifestations (lower limb edema, S3 gallop, neck veins congestion), and laboratory value (the mean Hb levels significantly increased from 11.96 ± 1.57 to 12.97 ± 1.36, while the median CRP significantly decreased from 7 (3-9) to 2 (1-3). As well, the median Pro-BNP significantly decreased from 89.5 (73-380) to 66.5 (53.5-151) following MV clipping. During the whole follow-up period, there was dramatic improvement in the NHYA functional class, echocardiographic assessment including left ventricular ejection fraction, and mitral regurge grade. During follow-up, four patients (20%) developed complications. There was no statistical difference between patients who developed complications and those who did not regarding their age (75.25 ± 12.42 versus 64.63 ± 9.21, respectively), BSA (1.69 ± 0.11 versus 1.79 ± 0.22, respectively), gender (75% versus 87.5% males respectively), MR etiology (75% versus 50% ischemic, 25% versus 50% non-ischemic), or NYHA pre- or post-mitral clipping. However, the median EuroSCORE was significantly higher in the complicated group (13, IQR= 11.5-14.5) than the non-complicated group (9.5, IQR=8.5-11.5).

Conclusion: Percutaneous usage of MitraClip for mitral valve repair showed favorable reliability and better clinical outcomes.

Trial Registration: ZU-IRB#2481-17-2-2016 Registered 17 February 2016, email: IRB_123@medicine.zu.edu.eg.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8093336PMC
http://dx.doi.org/10.1186/s43044-021-00166-5DOI Listing

Publication Analysis

Top Keywords

mitral valve
16
valve repair
16
left ventricular
16
ejection fraction
12
safety efficacy
8
efficacy outcomes
8
outcomes year
8
year mitraclip
8
percutaneous mitral
8
patients
8

Similar Publications

Repairing the mitral valve without touching the mitral valve-a novel technique.

J Surg Case Rep

January 2025

Department of Cardiac Surgery, Royal Papworth Hospital, Papworth Road, Cambridge Biomedical Campus, Cambridge, Cambridgeshire CB2 0AY, United Kingdom.

A 44-year-old gentleman presented with severe ischemic cardiomyopathy and mitral regurgitation post-inferior myocardial infarction. Echocardiography and magnetic resonance imaging revealed a dilated left ventricle with a large left ventricular aneurysm (9.3 × 9.

View Article and Find Full Text PDF

Post-capillary hypertension resulting from mitral regurgitation is typically considered a contraindication for single lung transplantation due to heightened risks of primary graft dysfunction. This case report highlights a 66-year-old COPD patient with severe mitral regurgitation who was deemed ineligible for surgical mitral replacement. As an alternative, transcatheter mitral valve replacement was successfully performed, resulting in the normalization of pulmonary artery pressures.

View Article and Find Full Text PDF

Peripheral Vascular Emboli in Patients with Infective Endocarditis are Common.

J Vasc Surg

January 2025

Department of Surgery, Division of Vascular and Endovascular Surgery, Boston Medical Center, Boston University Chobanian and Avedisian School of Medicine, Boston, MA, USA. Electronic address:

Objective: Infective endocarditis (IE) is associated with significant morbidity and mortality and places patients at risk for subsequent peripheral vascular emboli. Our goals were to analyze the incidence of peripheral emboli and their associated complications and outcomes.

Methods: A retrospective single-center review of all patients with IE from 2013-2021 was performed.

View Article and Find Full Text PDF

Purpose Of Review: This review aims to explore the complex interplay between atrial functional mitral regurgitation (AFMR), atrial fibrillation (AF), and heart failure with preserved ejection fraction (HFpEF). The goal is to define these conditions, examine their underlying mechanisms, and discuss treatment perspectives, particularly addressing diagnostic challenges.

Recent Findings: Recent research highlights the rising prevalence of AFMR, now accounting for nearly one-third of significant mitral regurgitation cases.

View Article and Find Full Text PDF

Automatic 4D mitral valve segmentation from transesophageal echocardiography: a semi-supervised learning approach.

Med Biol Eng Comput

January 2025

Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.

Performing automatic and standardized 4D TEE segmentation and mitral valve analysis is challenging due to the limitations of echocardiography and the scarcity of manually annotated 4D images. This work proposes a semi-supervised training strategy using pseudo labelling for MV segmentation in 4D TEE; it employs a Teacher-Student framework to ensure reliable pseudo-label generation. 120 4D TEE recordings from 60 candidates for MV repair are used.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!