A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of long-chain fatty acids in anaerobic digester supernatant and olive mill wastewater exploiting an in-syringe dispersive liquid-liquid microextraction and derivatization-free GC-MS method. | LitMetric

AI Article Synopsis

  • Long-chain fatty acids (LCFA) are significant in lipid-rich wastewaters and need to be analyzed effectively in anaerobic digesters.
  • A new method combining in-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction (DLLME) with gas chromatography-mass spectrometry (GC-MS) allows for rapid and precise LCFA analysis without needing derivatization.
  • This method shows excellent detection limits (0.01-0.05 mg L) and precision, successfully identifying palmitic, stearic, and oleic acids in samples from anaerobic digesters and olive mill wastewaters.

Article Abstract

Long-chain fatty acids (LCFA) are commonly found in lipid-rich wastewaters and are a key factor to monitor the anaerobic digesters. A new simple, fast, precise, and suitable method for routine analysis of LCFA is proposed. The system involves in-syringe-magnetic stirring-assisted dispersive liquid-liquid microextraction (DLLME) prior to gas chromatography-mass spectrometry (GC-MS) without a derivatization process. Calibration curves were prepared in an ethanol solution (R ≥ 0.996), which was also useful as disperser solvent. Hexane was chosen as the extraction solvent. Several parameters (pH, ionic strength, extraction solvent volume, stirring time) were optimized in multivariate and univariate studies. Limits of detection (LODs) were found in the range 0.01-0.05 mg L and good precision inter-day (RSDs≤7.9%) and intra-day (RSDs≤4.4%) were obtained. The method was applied to quantify LCFA in supernatants of anaerobic digesters and olive mill wastewaters (OMW). Palmitic, stearic, and oleic acids were the most abundant fatty acid in the analyzed samples and the relative recoveries for all of them were between 81 and 113%.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-021-03338-zDOI Listing

Publication Analysis

Top Keywords

long-chain fatty
8
fatty acids
8
olive mill
8
dispersive liquid-liquid
8
liquid-liquid microextraction
8
anaerobic digesters
8
extraction solvent
8
determination long-chain
4
acids anaerobic
4
anaerobic digester
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!