Joint line plate fixation for tibial plateau fractures caused by hyperextension varus.

Exp Ther Med

Department of Orthopaedics, Wuhan Fourth Hospital, Puai Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430032, P.R. China.

Published: June 2021

The present study evaluated the outcomes of internal fixation with a joint line plate in the treatment of tibial plateau fractures caused by hyperextension of the varus. The study included 25 cases (13 males and 12 females; age, 19-71 years) of tibial plateau fracture caused by hyperextension of the varus, which were treated at Puai Hospital, Tongji Medical College (Wuhan, China) between January 2015 and June 2017. Fractures were treated with internal fixations of the inner cortex with a self-clipped joint line plate made of steel. After the surgery, patients were examined immediately and at 3, 6 and 12 months. Healing was evaluated by X-ray examination. All cases were cured during follow-up. After surgery, one patient developed partial necrosis of the skin margin of the incision and recovered after a dressing change. Furthermore, one patient with a concomitant peroneal nerve injury and hypoesthesia recovered after treatment with neurotrophic drugs. No screw loosening, fractures or failure of the internal fixations occurred. According to the X-ray results, there were significant differences in the tibial plateau angle (TPA) and medial posterior slope angle (m-PSA) between the pre-operative stage and 12 months post-operatively (P<0.05). However, no significant differences in either the TPA or m-PSA were present between the immediate post-operative stage and 12 months post-operatively (P>0.05). In conclusion, internal fixation with a joint line plate is an appropriate treatment for tibial plateau fractures involving the anteromedial margin with good clinical efficacy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8082576PMC
http://dx.doi.org/10.3892/etm.2021.10053DOI Listing

Publication Analysis

Top Keywords

tibial plateau
20
joint plate
16
plateau fractures
12
caused hyperextension
12
hyperextension varus
12
fractures caused
8
varus study
8
internal fixation
8
fixation joint
8
treatment tibial
8

Similar Publications

Treatment of posterolateral tibial plateau fractures through the articular line approach.

BMC Musculoskelet Disord

January 2025

Department of Orthopedics, Lishui Central Hospital, Zhejiang, 323000, China.

Background: Posterolateral tibial plateau fractures pose significant challenges for orthopedic surgeons due to the anatomical risks associated with the posterolateral approach. Despite numerous surgical techniques available, there lacks a consensus on the optimal approach.

Methods: Articular line incision approach was employed on 12 patients suffering from posterolateral tibial plateau fractures.

View Article and Find Full Text PDF

Background: Bicondylar tibial plateau fractures are often associated with significant soft tissue compromise making operative treatment challenging. Dual plating through a two-incision approach following temporary external fixation has been shown to improve complication rates although deep infection rates remain high.The objective was to evaluate early outcomes following a novel technique of percutaneous application of the medial plate superficial to the pes anserinus tendons.

View Article and Find Full Text PDF

Introduction: Individuals with anterior cruciate ligament reconstruction (ACLR) often walk with a less dynamic vertical ground reaction force (vGRF), exemplified by a reduced first peak vGRF and elevated midstance vGRF compared to uninjured controls. However, the mechanism by which altered limb loading affects actual tibial plateau contact forces during walking remains unclear.

Methods: Our purpose was to use musculoskeletal simulation to evaluate the effects of first peak vertical ground reaction force (vGRF) biofeedback on bilateral tibiofemoral contact forces relevant to the development of post-traumatic osteoarthritis (OA) in 20 individuals with ACLR.

View Article and Find Full Text PDF

Background: To explore the advantages of a lateral tibial locking plate combined with Jail screw fixation in the treatment of anterolateral tibial plateau collapse fracture (ATPCF).

Methods: A retrospective analysis was conducted on patients with ATPCFs admitted to our hospital from February 2019 to February 2023. Twenty-six patients were successfully included, including 15 males and 11 females, with an average age of 58.

View Article and Find Full Text PDF

May a Single Presurgical High-Field MRI Sequence Replace Standard Radiographs for TPLO Surgical Planning in Dogs?

Vet Radiol Ultrasound

January 2025

Ospedale Veterinario "I Portoni Rossi", Anicura Italy, Diagnostic Imaging Department (Mattei, Specchi), Surgical Department (Pratesi), Neuroradiology Department (Bernardini), Bologna, Italy.

Cranial cruciate ligament (CCL) disease causes variable stifle instability assessed by specific clinical tests. Radiographs are performed to measure the tibial plateau angle (TPA) for planning tibial plateau leveling osteotomy (TPLO) surgery. Concomitant damage to other intra-articular structures, for which clinical detection is unreliable, may occur and potentially affect the surgical outcome.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!