The counting of microorganisms is essential in the area of microbiology, especially in the preparation of inoculum. The main methods for obtaining inoculum are McFarland standard, Neubauer chamber, and plate count. However, the visual comparison is subjective while the counting in the chamber and the plating are technically time-consuming. For this reason, our article aims to correlate the absorbance of the spectrophotometer in the visible ultraviolet region (UV-Vis) with the cell counting in the Neubauer chamber. This study used suspensions of Candida spp. measured at three wavelengths (530, 600, and 700 nm) and counting in a Neubauer chamber. In the next step, curves were adjusted with different polynomials using absorbances and counts. The two best polynomial curve fittings were the Saturation Growth Rate (SGR) and Morgan-Mercer-Flodin (MMF). Therefore, the polynomials were linearized and a direct correlation between absorbance and the number of cells was made. The proposed method proved to be more accurate (5 ± 0.5 × 10) than the comparison with the McFarland turbidity (1-5 x 10) and more practical than plate counting. Predicting the number of cells by UV-Vis is an alternative that reduces the uncertainty of the cell count interval for inoculum preparation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ab.2021.114216 | DOI Listing |
Diabetes Obes Metab
February 2025
Leicester Real World Evidence Unit, Diabetes Research Centre, University of Leicester, Leicester, UK.
Background: People hospitalised for coronavirus disease 2019 (COVID-19) have elevated incidence of diabetes. However, it is unclear whether this is due to shared risk factors, confounding or stress hyperglycaemia in response to acute illness.
Methods: We analysed a multicentre prospective cohort study (PHOSP-COVID) of people ≥18 years discharged from NHS hospitals across the United Kingdom following COVID-19.
Int J Epidemiol
February 2024
The Institute for Lung Health, NIHR Leicester Biomedical Research Centre-Respiratory, University of Leicester, Leicester, UK.
Diagnostics (Basel)
October 2024
Departments of Laboratory Medicine, College of Medicine, Korea University, Seoul 02841, Republic of Korea.
: Cerebrospinal fluid (CSF) analysis is essential for diagnosing various disorders affecting the central nervous system (CNS). Traditionally, CSF cell count analysis is performed manually using a Neubauer chamber hemocytometer, which is labor-intensive and prone to subjective interpretation. : In this study, we evaluated the analytical and clinical performance of the Microscanner C3, an automated cell counting system, for CSF analysis using artificially prepared samples and 150 clinical CSF samples.
View Article and Find Full Text PDFGlob Chang Biol
September 2024
Smithsonian Environmental Research Center, Edgewater, Maryland, USA.
Asian J Androl
January 2025
Department of Andrology/Sichuan Human Sperm Bank, West China Second University Hospital, Sichuan University, Chengdu 610000, China.
According to the World Health Organization (WHO) manual, sperm concentration should be measured using an improved Neubauer hemocytometer, while sperm motility should be measured by manual assessment. However, in China, thousands of laboratories do not use the improved Neubauer hemocytometer or method; instead, the Makler counting chamber is one of the most widely used chambers. To study sources of error that could impact the measurement of the apparent concentration and motility of sperm using the Makler counting chamber and to verify its accuracy for clinical application, 67 semen samples from patients attending the Department of Andrology, West China Second University Hospital, Sichuan University (Chengdu, China) between 13 September 2023 and 27 September 2023, were included.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!