Curve fitting and linearization of UV-Vis spectrophotometric measurements to estimate yeast in inoculum preparation.

Anal Biochem

Laboratório de Pesquisa em Micologia Aplicada, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS, Brazil; Programa de Pós-Graduação em Ciências Farmacêuticas, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS, Brazil.

Published: July 2021

The counting of microorganisms is essential in the area of microbiology, especially in the preparation of inoculum. The main methods for obtaining inoculum are McFarland standard, Neubauer chamber, and plate count. However, the visual comparison is subjective while the counting in the chamber and the plating are technically time-consuming. For this reason, our article aims to correlate the absorbance of the spectrophotometer in the visible ultraviolet region (UV-Vis) with the cell counting in the Neubauer chamber. This study used suspensions of Candida spp. measured at three wavelengths (530, 600, and 700 nm) and counting in a Neubauer chamber. In the next step, curves were adjusted with different polynomials using absorbances and counts. The two best polynomial curve fittings were the Saturation Growth Rate (SGR) and Morgan-Mercer-Flodin (MMF). Therefore, the polynomials were linearized and a direct correlation between absorbance and the number of cells was made. The proposed method proved to be more accurate (5 ± 0.5 × 10) than the comparison with the McFarland turbidity (1-5 x 10) and more practical than plate counting. Predicting the number of cells by UV-Vis is an alternative that reduces the uncertainty of the cell count interval for inoculum preparation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ab.2021.114216DOI Listing

Publication Analysis

Top Keywords

neubauer chamber
12
inoculum preparation
8
counting neubauer
8
number cells
8
counting
5
curve fitting
4
fitting linearization
4
linearization uv-vis
4
uv-vis spectrophotometric
4
spectrophotometric measurements
4

Similar Publications

Background: People hospitalised for coronavirus disease 2019 (COVID-19) have elevated incidence of diabetes. However, it is unclear whether this is due to shared risk factors, confounding or stress hyperglycaemia in response to acute illness.

Methods: We analysed a multicentre prospective cohort study (PHOSP-COVID) of people ≥18 years discharged from NHS hospitals across the United Kingdom following COVID-19.

View Article and Find Full Text PDF

Evaluation of the Microscanner C3 for Automated Cell Counting in Cerebrospinal Fluid Analysis.

Diagnostics (Basel)

October 2024

Departments of Laboratory Medicine, College of Medicine, Korea University, Seoul 02841, Republic of Korea.

: Cerebrospinal fluid (CSF) analysis is essential for diagnosing various disorders affecting the central nervous system (CNS). Traditionally, CSF cell count analysis is performed manually using a Neubauer chamber hemocytometer, which is labor-intensive and prone to subjective interpretation. : In this study, we evaluated the analytical and clinical performance of the Microscanner C3, an automated cell counting system, for CSF analysis using artificially prepared samples and 150 clinical CSF samples.

View Article and Find Full Text PDF
Article Synopsis
  • * Annual CH fluxes averaged around 26g CH/m²/year; the highest emissions were linked with certain temperature and salinity conditions, particularly in fresh-oligohaline marshes.
  • * The research found that salinity was the main factor affecting annual CH fluxes, while temperature, gross primary productivity, and tidal height influenced shorter-term variability, providing crucial data for better estimating methane emissions in these ecosystems.
View Article and Find Full Text PDF

According to the World Health Organization (WHO) manual, sperm concentration should be measured using an improved Neubauer hemocytometer, while sperm motility should be measured by manual assessment. However, in China, thousands of laboratories do not use the improved Neubauer hemocytometer or method; instead, the Makler counting chamber is one of the most widely used chambers. To study sources of error that could impact the measurement of the apparent concentration and motility of sperm using the Makler counting chamber and to verify its accuracy for clinical application, 67 semen samples from patients attending the Department of Andrology, West China Second University Hospital, Sichuan University (Chengdu, China) between 13 September 2023 and 27 September 2023, were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!