A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of the Criteria to Distinguish Left Bundle Branch Pacing From Left Ventricular Septal Pacing. | LitMetric

Evaluation of the Criteria to Distinguish Left Bundle Branch Pacing From Left Ventricular Septal Pacing.

JACC Clin Electrophysiol

Department of Cardiology, the First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China; The Key Lab of Cardiovascular Disease, Science and Technology of Wenzhou, Wenzhou, China. Electronic address:

Published: September 2021

Objectives: This study sought to assess the predictive value of the proposed electrocardiogram and intracardiac electrogram characteristics for confirmation of left bundle branch (LBB) capture.

Background: Previously proposed criteria to distinguish left bundle branch pacing (LBBP) and left ventricular septum (LVS) pacing (LVSP) have not been fully validated.

Methods: A His bundle pacing lead, an LBBP lead, and a multielectrode catheter at the LVS were placed. Direct LBB capture was defined as demonstration of retrograde His potential on the His bundle pacing lead and/or anterograde left conduction system potentials on the multielectrode catheter during LBBP. The routinely used parameters-His, LBB potential, time from stimulus to peak ventricular activation (Stim-LVAT), and paced QRS morphology during LVSP and LBBP at various depths and outputs were analyzed.

Results: Thirty patients (21 non-left bundle branch block [LBBB], 9 LBBB) who demonstrated direct LBB capture using the defined criteria were included. The proportion of paced right bundle branch block was 100% during LBB capture in all patients compared to 23.4% in non-LBBB and 44.4% in LBBB during LVSP. LBB potential was recorded in all patients during intrinsic rhythm (non-LBBB group) or His corrective pacing in LBBB. Paced QRS duration was longer during selective LBBP compared to nonselective LBBP or LVSP only. All patients with characteristics of selective LBBP or abrupt decrease in Stim-LVAT of ≥10 ms demonstrated LBB capture.

Conclusions: Direct LBB capture can be confirmed by recording retrograde His potential and anterograde left conduction system potentials. Abrupt decrease in Stim-LVAT of ≥10 ms and demonstration of selective LBBP could be used as simple criteria to confirm LBB capture.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacep.2021.02.018DOI Listing

Publication Analysis

Top Keywords

bundle branch
20
lbb capture
20
left bundle
12
direct lbb
12
selective lbbp
12
lbb
9
criteria distinguish
8
distinguish left
8
branch pacing
8
lbbp
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!