Objectives: Contrary to leisure-time physical activity, occupational physical activity (OPA) may have harmful health effects, called the physical activity paradox. A proposed mechanism is that OPA can elevate the heart rate (HR) for several hours per day. We aimed to investigate the association between the mean intensity of OPA and HR variability (HRV) indices the following night.

Methods: Three cohorts (NOMAD, DPhacto, and Physical Workload and Fitness) involving blue-collar workers from different sectors were merged in this study. HR monitors (Actiheart) recorded 24-hour inter-beat intervals (IBI) for up to four consecutive days. The relative intensity of the mean HR during work was estimated by HR reserve (%HRR), and time-domain indices of HRV were analyzed during the following night. Data were analyzed using a multilevel growth model to test the association between mean %HRR during work and HRV indices at night in a day-by-day analysis adjusted for age, BMI, alcohol consumption, smoking, and occupation.

Results: The dataset included a sample of 959 Danish blue-collar workers, with a mean %HRR during work of 31%, and 42% worked at an intensity ≥30%HRR. The multilevel model showed negative within- and between-subject associations between %HRR during work and HRV indices at night.

Conclusions: Our results indicate a higher %HRR during work to associate with lower HRV indices the following night and a higher HR, reflecting an imbalanced autonomic cardiac modulation. This finding supports a high mean HR during work to be a potential underlying mechanism for the harmful health effect of OPA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8259705PMC
http://dx.doi.org/10.5271/sjweh.3965DOI Listing

Publication Analysis

Top Keywords

physical activity
16
hrv indices
16
%hrr work
16
heart rate
12
blue-collar workers
12
night day-by-day
8
activity paradox
8
harmful health
8
work hrv
8
indices night
8

Similar Publications

Studies on the Virucidal Effects of UV-C of 233 nm and 275 nm Wavelengths.

Viruses

December 2024

Institute of Hygiene and Environmental Medicine, University Medicine Greifswald, Ferdinand-Sauerbruch-Str., 17475 Greifswald, Germany.

Among the physical decontamination methods, treatment with ultraviolet (UV) radiation is a suitable means of preventing viral infections. Mercury vapor lamps (254 nm) used for room decontamination are potentially damaging to human skin (radiation) and harmful to the environment (mercury). Therefore, other UV-C wavelengths (100-280 nm) may be effective for virus inactivation on skin without damaging it, e.

View Article and Find Full Text PDF

Flexible high-deflection strain gauges have been demonstrated to be cost-effective and accessible sensors for capturing human biomechanical deformations. However, the interpretation of these sensors is notably more complex compared to conventional strain gauges, particularly during dynamic motion. In addition to the non-linear viscoelastic behavior of the strain gauge material itself, the dynamic response of the sensors is even more difficult to capture due to spikes in the resistance during strain path changes.

View Article and Find Full Text PDF

Safety of Immersive Virtual Reality for the Management of Parkinson's Disease.

Sensors (Basel)

December 2024

Centro de Estudos Egas Moniz, Faculdade de Medicina, Universidade de Lisboa, 1649-028 Lisbon, Portugal.

Virtual reality (VR) has been used in research and clinical practice in the management of Parkinson's disease (PD), potentially enhancing physiotherapy. Adverse events (AEs) associated with VR applications in PD have been poorly explored. We conducted a randomized controlled trial to compare two 12-week interventions using physiotherapy and immersive VR, and analyzed the frequency and type of AEs occurring in 30 people with PD.

View Article and Find Full Text PDF

Inappropriate, excessive, or overly strenuous training of sport horses can result in long-term injury, including the premature cessation of a horse's sporting career. As a countermeasure, this study demonstrates the easy implementation of a biomechanical load monitoring system consisting of five commercial, multi-purpose inertial sensor units non-invasively attached to the horse's distal limbs and trunk. From the data obtained, specific parameters for evaluating gait and limb loads are derived, providing the basis for objective exercise load management and successful injury prevention.

View Article and Find Full Text PDF

Foot strike patterns influence vertical loading rates during running. Running retraining interventions often include switching to a new foot strike pattern. Sudden changes in the foot strike pattern may be uncomfortable and may lead to higher step-to-step variability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!