AI Article Synopsis

  • The study explores how measuring force patterns in ski boots can enhance performance and safety while skiing.
  • A methodology for continuous data acquisition of these forces is discussed, including analysis of skiing styles and techniques related to falling mechanisms.
  • Instrumented ski boots with specific force sensors help improve understanding of skiing dynamics to inform better release conditions for bindings and overall skiing technique.

Article Abstract

In skiing, performance and safety can depend on small details. Consequently, the measurement of forces within the ski boots, which represent the essential form-fitting and force transmitting interface during skiing, will lead to enhanced performance and more importantly safety. This study presents a methodology to measure force patterns (continuous data acquisition) under laboratory as well as realistic slope conditions. The force measurements will be analyzed to gain insights of the skiing style, skiing technique, specific falling mechanisms (i.e., boot induced anterior drawer, phantom foot, hyperextension of the knee joint, and valgus-external rotation). Furthermore, the locations of force sensors in a designed ski boot are discussed in terms of practicability and applicability. These insights are of particular interest to derive release conditions for predictive binding systems and furthermore provide data to improve the style of skiing (e.g., turn release action or center of gravity behavior). For that purpose, a ski boot was instrumented with seven force (piezoresistive) sensors while the basic structure of the boot and the binding remained unchanged. Three sensors were placed on the insole to measure ground reaction forces as well as the contact forces between the skier's foot and the boot. The other four sensors were positioned at spoiler/shaft and toecap (front sole) regions of the ski boot. The locations of the force sensors within the ski-boot are defined with regard to the main body movement while skiing (body-related planes). In addition, a commercially available ski and body mount measuring system were utilized to correlate speed, inclination and body position with the force patterns occurring during skiing on the slope as well as simulating specific body positions on an inclined ramp under laboratory conditions. The measured force revealed that the toecap (upper) sensors provide insufficient even non-conclusive data to deduce significant patterns. However, the insole sensors (heel and front sole area) as well as the spoiler/shaft (back) sensors are more reliable and show characteristic patterns indicating forward or backward lean. These results will have an important impact to the development of predictiveelectro-mechanical bindings to prevent knee-related injuries, which, from a statistical point of view, concerns largely women and young athletes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8077231PMC
http://dx.doi.org/10.3389/fspor.2021.557849DOI Listing

Publication Analysis

Top Keywords

ski boot
16
force patterns
12
falling mechanisms
8
force
8
style skiing
8
locations force
8
sensors
8
force sensors
8
front sole
8
boot
7

Similar Publications

Evaluating wrapping alpine ski boots during on-snow carving.

Front Sports Act Living

July 2023

Performance Fit Laboratory, BOA Technology Inc., Denver, CO, United States.

Introduction: Alpine ski boots enable rapid and precise force transfer between skier and ski while carving. These boots are made of rigid plastic and fit tightly commonly through four buckles. Such a fit can improve speed and control but also pain and discomfort.

View Article and Find Full Text PDF

Background: In recreational alpine skiing ACL injury risk depends on the interaction of individual characteristics and behaviours as well as on equipment-related factors.

Aim: to evaluate if and to what extent personal characteristics and equipment-related parameters are associated with ACL injury risk in cautious and risk-taking recreational alpine skiers.

Methods: A retrospective questionnaire-based, case-control study of ACL-injured and uninjured in a cohort of cautious as well as risk-taking recreational skiers was conducted.

View Article and Find Full Text PDF

In ski mountaineering it is the goal to reach the top of a mountain by sheer muscle force. The specific equipment (flexible boot, only toe fixated binding, and a skin on the ski to prevent from slipping backwards) enables the skier to move up the hill ergonomically, where the heel part of the binding offers a special adaptation possibility. The so-called riser height supports the heel standing height and can be adjusted to individually preferred settings.

View Article and Find Full Text PDF

Skiing technique, and performance are impacted by the interplay between ski and snow. The resulting deformation characteristics of the ski, both temporally and segmentally, are indicative of the unique multi-faceted nature of this process. Recently, a PyzoFlex ski prototype was presented for measuring the local ski curvature (w″), demonstrating high reliability and validity.

View Article and Find Full Text PDF

Background: In recreational alpine skiing, the anterior cruciate ligament (ACL) is affected in approximately 50% of serious knee injuries. There are established sex-based and skill-based differences in ACL injury risk, but the potential impact of equipment used (eg, skis, bindings, and boots) has not been evaluated.

Purpose: To evaluate individual and equipment-related risk factors for an ACL injury depending on sex and skill level.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!