Background: The randomized SOLVE-TAVI (compariSon of secOnd-generation seLf-expandable vs. balloon-expandable Valves and gEneral vs. local anesthesia in Transcatheter Aortic Valve Implantation) trial compared newer-generation self-expanding valves (SEV) and balloon-expandable valves (BEV) as well as local anesthesia with conscious sedation (CS) and general anesthesia (GA) in patients undergoing transfemoral transcatheter aortic valve replacement (TAVR). Both strategies showed similar outcomes at 30 days.

Objectives: The purpose of this study was to compare clinical outcomes during 1-year follow-up in the randomized SOLVE-TAVI trial.

Methods: Using a 2 × 2 factorial design 447 intermediate- to high-risk patients with severe, symptomatic aortic stenosis were randomly assigned to transfemoral TAVR using either the SEV (Evolut R, Medtronic Inc., Minneapolis, Minnesota) or the BEV (Sapien 3, Edwards Lifesciences, Irvine, California) as well as CS or GA at 7 sites.

Results: In the valve-comparison strategy, rates of the combined endpoint of all-cause mortality, stroke, moderate or severe paravalvular leakage, and permanent pacemaker implantation were similar between the BEV and SEV group (n = 84, 38.3% vs. n = 87, 40.4%; hazard ratio: 0.94; 95% confidence interval: 0.70 to 1.26; p = 0.66) at 1 year. Regarding the anesthesia comparison, the combined endpoint of all-cause mortality, stroke, myocardial infarction, and acute kidney injury occurred with similar rates in the GA and CS groups (n = 61, 25.7% vs. n = 54, 23.8%; hazard ratio: 1.09; 95% confidence interval: 0.76 to 1.57; p = 0.63).

Conclusions: In intermediate- to high-risk patients undergoing transfemoral TAVR, newer-generation SEV and BEV as well as CS and GA showed similar clinical outcomes at 1 year using a combined clinical endpoint. (SecOnd-generation seLf-expandable Versus Balloon-expandable Valves and gEneral Versus Local Anesthesia in TAVI [SOLVE-TAVI]; NCT02737150).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacc.2021.03.007DOI Listing

Publication Analysis

Top Keywords

clinical outcomes
12
transcatheter aortic
12
aortic valve
12
balloon-expandable valves
12
local anesthesia
12
valve replacement
8
randomized solve-tavi
8
second-generation self-expandable
8
valves general
8
bev well
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!