AI Article Synopsis

  • Field-portable methods for measuring particulate matter (PM) are crucial for public health, but existing techniques face challenges like real-time measurement and bulky equipment.
  • The authors propose a new optical method using side-illuminated total internal reflection (TIR) that provides fast, accurate PM analysis and better image contrast in a smaller device.
  • Their results show significant improvements in signal-to-noise ratios for detecting both microbeads and fine dust particles compared to traditional methods, and they successfully tested this approach using a low-cost smartphone toy microscope.

Article Abstract

Field-portable observation and analysis of particulate matter (PM) is required to enhance healthy lives. Various types of the PM measurement methods are in use; however, each of these methods has significant limitations in that real time measurement is impossible, the detection system is bulky, or the measurement accuracy is insufficient. In this work, we introduce an optical method to perform a fast and accurate PM analysis with a higher-contrast microscopic image enabled by a side-illuminated total internal reflection (TIR) technique to be implemented in a compact device. The superiority of the proposed method was quantitatively demonstrated by comparing the signal-to-noise ratio of the proposed side-illuminated TIR method with a traditional halogen lamp-based transmission microscope. With the proposed device, signal-to-noise ratios (SNRs) for microbeads (5~20 µm) and ultrafine dust particles (>5 µm) increased 4.5~17 and 4~10 dB, respectively, compared to the conventional transmission microscope. As a proof of concept, the proposed method was also applied to a low-cost commercial smartphone toy microscope enabling field-portable detection of PMs. We believe that the proposed side-illuminated TIR PM detection device holds significant advantages over other commonly used systems due to its sufficient detection capability along with simple and compact configuration as well as low cost.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8070112PMC
http://dx.doi.org/10.3390/s21082745DOI Listing

Publication Analysis

Top Keywords

side-illuminated total
8
total internal
8
internal reflection
8
proposed method
8
proposed side-illuminated
8
side-illuminated tir
8
transmission microscope
8
detection
5
proposed
5
detection particulate
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!