The Oticon Medical Neuro cochlear implant system includes the modes Opti Omni and Speech Omni, the latter providing beamforming (i.e., directional selectivity) in the high frequencies. Two studies compared sentence identification scores of adult cochlear implant users with Opti Omni and Speech Omni. In Study 1, a double-blind longitudinal crossover study, 12 new users trialed Opti Omni or Speech Omni (random allocation) for three months, and their sentence identification in quiet and noise (+10 dB signal-to-noise ratio) with the trialed mode were measured. The same procedure was repeated for the second mode. In Study 2, a single-blind study, 11 experienced users performed a speech identification task in quiet and at relative signal-to-noise ratios ranging from -3 to +18 dB with Opti Omni and Speech Omni. The Study 1 scores in quiet and in noise were significantly better with Speech Omni than with Opti Omni. Study 2 scores were significantly better with Speech Omni than with Opti Omni at +6 and +9 dB signal-to-noise ratios. Beamforming in the high frequencies, as implemented in Speech Omni, leads to improved speech identification in medium levels of background noise, where cochlear implant users spend most of their day.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8167646PMC
http://dx.doi.org/10.3390/audiolres11020016DOI Listing

Publication Analysis

Top Keywords

speech omni
28
opti omni
24
cochlear implant
16
omni speech
16
omni
13
high frequencies
12
omni study
12
speech
9
oticon medical
8
medical neuro
8

Similar Publications

Patient-Perceived Vocal Effort Immediately Following Voice Tasks in Adductor Laryngeal Dystonia (ADLD).

J Voice

December 2024

Department of Speech and Hearing Sciences, University of Washington, Seattle, Washington; Department of Speech, Language, and Hearing Sciences, Boston University, Boston, Massachusetts.

Purpose: This study examined the relationship between patient-perceived vocal effort (VE) using a 100-mm visual analog scale (VE-VAS) and the OMNI Vocal Effort Scale (OMNI-VES) when measures were obtained after a vocal activity. A second purpose was to evaluate how VE related to other voice assessment measures.

Method: Fifty-three speakers with adductor laryngeal dystonia (ADLD) provided speech recordings.

View Article and Find Full Text PDF

Relationship Between Working Memory, Compression, and Beamformers in Ideal Conditions.

Ear Hear

November 2024

Department of Communication Sciences & Disorders, Northwestern University, Evanston, Illinois, USA.

Objectives: Previous research has shown that speech recognition with different wide dynamic range compression (WDRC) time-constants (fast-acting or Fast and slow-acting or Slow) is associated with individual working memory ability, especially in adverse listening conditions. Until recently, much of this research has been limited to omnidirectional hearing aid settings and colocated speech and noise, whereas most hearing aids are fit with directional processing that may improve the listening environment in spatially separated conditions and interact with WDRC processing. The primary objective of this study was to determine whether there is an association between individual working memory ability and speech recognition in noise with different WDRC time-constants, with and without microphone directionality (binaural beamformer or Beam versus omnidirectional or Omni) in a spatial condition ideal for the beamformer (speech at 0 , noise at 180 ).

View Article and Find Full Text PDF

Multilingual feasibility of GPT-4o for automated Voice-to-Text CT and MRI report transcription.

Eur J Radiol

January 2025

School of Medicine and Health, Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, TUM University Hospital, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany.

Purpose: Large language models (LLMs) promise to streamline radiology reporting. With the release of OpenAI's GPT-4o (Generative Pre-trained Transformers-4 omni), which processes not only text but also speech, multimodal LLMs might now also be used as medical speech recognition software for radiology reporting in multiple languages. This proof-of-concept study investigates the feasibility of using GPT-4o for automated voice-to-text transcription of radiology reports in English and German.

View Article and Find Full Text PDF

In Japan, the excessive length of time required for nursing records has become a social problem. A shift to concise "bulleted" records is needed to apply speech recognition and to work with foreign caregivers. Therefore, using 96,000 descriptively described anonymized nursing records, we identified typical situations for each information source and attempted to convert them to "bulleted" records using ChatGPT-3.

View Article and Find Full Text PDF

"Lombard Effect" and Voice Changes in Adductor Laryngeal Dystonia: A Pilot Study.

Laryngoscope

August 2024

Unità Operativa Complessa di Otorinolaringoiatria, Dipartimento di Neuroscienze, Organi di Senso e Torace, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.

Objectives: The aim was to describe the acoustic, auditory-perceptive, and subjective voice changes under the Lombard effect (LE) in adductor laryngeal dystonia (AdLD) patients.

Methods: Subjective perception of vocal effort (OMNI Vocal Effort Scale OMNI-VES), Maximum Phonation Time (MPT), and the perceptual severity of dysphonia (GRBAS scale) were assessed in condition of stillness and under LE in 10 AdLD patients and in 10 patients with typical voice. Speakers were asked to produce the sustained vowel /a/ and to read a phonetically balanced text aloud.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!