Alkali-activated cement (AAC) is a promising binder that replaces ordinary Portland cement (OPC). In this study, the development of setting time and strength of AAC mixes were studied using ultrasonic testing method. The test results were compared with traditional Vicat setting time and compressive and flexural strengths. The findings showed that setting times and strengths have a strong correlation with ultrasonic velocity curve. The initial setting time corresponds well with the ultrasonic velocity curve's dormant period, and the final setting time with the time it takes to reach the velocity curve's maximum acceleration. Both setting times also showed a correlation with the value of the maximum acceleration. An exponential relation was found between the ultrasonic velocity and the compressive and flexural strengths. The effect of binder content, alkaline solid to binder ratio (AS/B), sodium silicate to sodium hydroxide solids ratio (SS/SH), and total water to total solid binder ratio (TW/TS) on the strength and setting time are also studied using Taguchi method of experimental design. AS/B ratio showed a significant influence on the setting time of AAC while TW/TS ratio showed only a minor effect. The ultrasonic velocities were able to capture the effect of the different parameters similar to the compressive strength. The velocity decreased mainly with the increase of TW/TS ratio and binder content, while AS/B and SS/SH ratios showed a lower influence.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8069208 | PMC |
http://dx.doi.org/10.3390/ma14081889 | DOI Listing |
In total joint arthroplasty, periprosthetic joint infection (PJI) can be devastating. Corticosteroid injections (CSIs) are commonly administered for temporary pain relief in the setting of various conditions. Therefore, the current systematic review aims to evaluate whether CSIs administered prior to total shoulder arthroplasty (TSA) are a risk factor for PJI and revision surgery.
View Article and Find Full Text PDFObjective: We investigated use of hearing care among US veterans and explore motivations, barriers, and adherence to hearing healthcare.
Study Design: Cross-sectional online survey.
Setting: US Veterans.
Ann Thorac Surg Short Rep
September 2023
Department of Thoracic and Cardiovascular Surgery, Heart, Vascular & Thoracic Institute, Cleveland Clinic Florida, Weston, Florida.
Late presentation of an anomalous left coronary artery from the pulmonary artery (ALCAPA) syndrome is uncommon because of the low survival rates past infancy. Different operative procedures have been described, often combined with coronary bypass grafting. However, none of these approaches address the difficulty in dissecting out the aortic root and infundibulum because of collateral circulation, often dense in the elderly.
View Article and Find Full Text PDFBehav Anal Pract
December 2024
Department of Pediatrics, University of Michigan Medical School, Ann Arbor, MI USA.
Unlabelled: Collecting data and logging behaviors of clients who have autism spectrum disorder (ASD) during applied behavior analysis (ABA) therapy sessions can be challenging in real time, especially when the behaviors require a rapid response, like self-injury or aggression. Little information is available about the automation of data collection in ABA therapy, such as through machine learning (ML). Our survey of ABA therapists nationally revealed mixed levels of familiarity with ML and generally neutral responses to statements endorsing the benefits of ML.
View Article and Find Full Text PDFIndian J Nucl Med
November 2024
Department of Nuclear Medicine and Molecular Imaging, Homi Bhabha Cancer Hospital and Mahamana Pandit Madan Mohan Malaviya Cancer Centre, Tata Memorial Centre, Homi Bhabha National Institute, Varanasi, Uttar Pradesh, India.
Background: Prostate-specific membrane antigen (PSMA) has shown to be a promising agent for prostate cancer imaging under PET-CT. With the automation in radiolabeling with 68Ga, using iTG 68Ge/68Ga generator, it has helped introduce various new diagnostic agents and achieve good manufacturing practices (GMP) simultaneously. However, before any radiopharmaceutical is put into clinical usage, it should always be checked for its radiochemical purity and other quality parameters before injecting in the patient.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!