The present work was undertaken to determine the critical water temperature (Tcw), defined as the lowest water temperature a subject can tolerate at rest for 3 h without shivering, of wet-suited subjects during water immersion at different ambient pressures. Nine healthy males wearing neoprene wet suits (5 mm thick) were subjected to immersion to the neck in water at 1, 2, and 2.5 ATA while resting for 3 h. Continuous measurements of esophageal (T(es)) and skin (Tsk) temperatures and heat loss from the skin (Htissue) and wet suits (Hsuit) were recorded. Insulation of the tissue (Itissue), wet suits (Isuit), and overall total (Itotal) were calculated from the temperature gradient and the heat loss. The Tcw increased curvilinearly as the pressure increased, whereas the metabolic heat production during rest and immersion was identical over the range of pressure tested. During the 3rd h of immersion, Tes was identical under all atmospheric pressures; however, Tsk was significantly higher (P less than 0.05) at 2 and 2.5 ATA compared with 1 ATA. A 42 (P less than 0.001) and 50% (P less than 0.001), reduction in Isuit from the 1 ATA value was detected at 2 and 2.5 ATA, respectively. However, overall mean Itissue was maximal and independent of the pressure during immersion at Tcw. The Itotal was also significantly smaller in 2 and 2.5 ATA compared with 1 ATA. The Itissue provided most insulation in the extremities, such as the hand and foot, and the contribution of Isuit in these body parts was relatively small. On the other hand, Itissue of the trunk areas, such as the chest, back, and thigh, was not high compared with the extremities, and Isuit played a major role in the protection of heat drain from these body parts.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1152/jappl.1988.64.5.1916 | DOI Listing |
Cochrane Database Syst Rev
May 2023
Physiotherapy, UCL Great Ormond Street Institute of Child Health, London, UK.
Background: Cystic fibrosis (CF) is an inherited life-limiting disorder. Over time persistent infection and inflammation within the lungs contribute to severe airway damage and loss of respiratory function. Chest physiotherapy, or airway clearance techniques (ACTs), are integral in removing airway secretions and initiated shortly after CF diagnosis.
View Article and Find Full Text PDFWilderness Environ Med
June 2023
Faculty of Kinesiology and Recreation Management, University of Manitoba, Winnipeg, Manitoba, Canada; Faculty of Medicine, Departments of Anesthesia and Emergency Medicine, University of Manitoba, Winnipeg, Manitoba, Canada. Electronic address:
John Hayward, PhD (1937-2012), was an early and significant contributor to the understanding of cold water immersion physiology and survival. This article summarizes his work on the 50th anniversary of his first publication in this area. He described areas of high heat loss and emphasized the importance of protecting these areas during cold exposure using the Heat Escape Lessening Posture (HELP) and the potential for heat donation to these areas during rewarming.
View Article and Find Full Text PDFInt J Circumpolar Health
December 2023
Defence Research and Development Canada, Toronto, Canada.
A field study was conducted to examine the vulnerability of military divers to non-freezing cold injury (NFCI) during Arctic ice-diving operations. Participants were instrumented with temperature sensors on the back of their hands and on the bottom of their big toe for each dive to measure cooling of their extremities. While NFCI was not diagnosed in any of the participants during this field study, the data indicate that the feet were particularly vulnerable during the dives given that they were mostly in a temperature zone that could cause pain and performance decrements.
View Article and Find Full Text PDFNanotechnology
September 2022
Laboratory of Nanomaterials, Center for Photonic Science and Engineering, Skolkovo Institute of Science and Technology, Nobel St., 3, Moscow 121205, Russia.
Design of new smart prosthetics or robotic grippers gives a major impetus to low-cost manufacturing and rapid prototyping of force sensing devices. In this paper, we examine piezoresistive force sensors based on carbon nanotube fibers fabricated by a novel wet pulling technique. The developed sensor is characterized by an adjustable force range coupled with high sensitivity to enable the detection of a wide range of forces and displacements limited by the experimental setup only.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!