Background: To compare four different optical coherence tomography (OCT) devices for visualization of retinal and subretinal layers in highly myopic eyes.

Methods: In this prospective, observational, cross-sectional study, consecutive patients with high myopia and control subjects were imaged by four OCT devices: Spectralis OCT2, PlexElite 2.0 100 kHz, PlexElite 2.0 200 kHz and the Canon Xephilio OCT-S1. The acquisition protocol for comparison consisted of single vertical and horizontal line scans centered on the fovea. Comparison between the devices in the extent of visible retina, presence of conjugate image or mirror artifacts, visibility of the sclerochoroidal interface and retrobulbar tissue.

Results: 30 eyes with high myopia and 30 control subjects were analyzed. The visualized RPE length was significantly different between the OCT devices with Xephilio OCT-S1 imaging the largest extent ( < 0.0001). The proportion of eyes with conjugate image artifact was significantly higher with the Spectralis OCT ( < 0.0001), and lower with the PlexElite 200 kHz ( < 0.0001). No difference in visibility of the sclerochoroidal interface was noted among instruments. The retrobulbar tissue was visible in a higher proportion of eyes using swept-source PlexElite 100 kHz and 200 kHz ( < 0.007) compared to the other devices.

Conclusions: In highly myopic eyes, the four OCT devices demonstrated significant differences in the extent of the retina imaged, in the prevalence of conjugate image artifact, and in the visualization of the retrobulbar tissue.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8067388PMC
http://dx.doi.org/10.3390/diagnostics11040658DOI Listing

Publication Analysis

Top Keywords

oct devices
16
high myopia
12
200 khz
12
conjugate image
12
optical coherence
8
coherence tomography
8
eyes high
8
highly myopic
8
myopia control
8
control subjects
8

Similar Publications

Background: Methadone is commonly utilized to treat opioid use disorder (OUD). Requirements to visit an opioid treatment provider (OTP) clinic for methadone treatment limits access to treatment, impacts quality of life, and reduces OUD treatment program retention. The Computerized Oral Prescription Administration (COPA) system is a dual-biometric dispensing device for take-home dosing that could reduce the impacts of methadone administration on patients and clinic staff.

View Article and Find Full Text PDF

Study Objective: We present the results of the first feasibility and safety study of a novel multi-modality falloposcope, in 19 volunteers. The falloposcope incorporated multispectral fluorescence imaging (MFI) and optical coherence tomography (OCT) for evaluation of the fallopian tubes (FT).

Methods: Nineteen females undergoing elective salpingectomy were recruited in this IRB-approved study.

View Article and Find Full Text PDF

Purpose: This study aims to develop a deep-learning-based software capable of detecting and differentiating microaneurysms (MAs) as hyporeflective or hyperreflective on structural optical coherence tomography (OCT) images in patients with non-proliferative diabetic retinopathy (NPDR).

Methods: A retrospective cohort of 249 patients (498 eyes) diagnosed with NPDR was analysed. Structural OCT scans were obtained using the Heidelberg Spectralis HRA + OCT device.

View Article and Find Full Text PDF

Metal-organic frameworks (MOFs) are porous, ordered arrays formed by coordination bonds between organic ligands and metal ions or clusters. The highly tunable properties of the MOF structure and performance make it possible to meet the needs of many applications. Conductive MOFs are essential in the domain of sensing due to their electrical conductivity, porosity, and catalytic properties, offering an effective platform for detection.

View Article and Find Full Text PDF

Background: Noise-induced hearing loss (NIHL) in children is a growing public health concern due to increased exposure to high noise levels in various environments. Early intervention is crucial to prevent long-term developmental and social impacts. This study evaluates the effectiveness of earmuffs as a protective intervention in managing NIHL in children.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!