AI Article Synopsis

Article Abstract

In recent times, the application of the use of ion-selective electrodes has expanded in the field of pharmaceutical analyses due to their distinction from other sensors in their high selectivity and low cost of measurement, in addition to their high measurement sensitivity. Cost-effective, reliable, and robust all-solid-state potentiometric selective electrodes were designed, characterized, and successfully used for pholcodine determination. The design of the sensor device was based on the use of a screen-printed electrode modified with multiwalled carbon nanotubes (MWCNTs) as a solid-contact transducer. Tailored pholcodine (PHO) molecularly imprinted polymers (MIPs) were prepared, characterized, and used as sensory receptors in the presented potentiometric sensing devices. The sensors exhibited a sensitivity of 31.6 ± 0.5 mV/decade ( = 5, = 0.9980) over the linear range of 5.5 × 10 M with a detection limit of 2.5 × 10 M. Real serum samples in addition to pharmaceutical formulations containing PHO were analyzed, and the results were compared with those obtained by the conventional standard liquid chromatographic approach. The presented analytical device showed an outstanding efficiency for fast, direct, and low-cost assessment of pholcodine levels in different matrices.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8067864PMC
http://dx.doi.org/10.3390/polym13081192DOI Listing

Publication Analysis

Top Keywords

all-solid-state potentiometric
8
imprinted polymers
8
pholcodine determination
8
potentiometric ion-sensors
4
ion-sensors based
4
based tailored
4
tailored imprinted
4
pholcodine
4
polymers pholcodine
4
determination times
4

Similar Publications

Waterborne pathogens are harmful microorganisms transmitted through water sources. Early and rapid pathogen detection is important for preventing illnesses and implementing stringent water safety measures to minimize the risk of contamination. This work introduces a miniaturized all-solid-state potentiometric ion flux immunosensor for the rapid and label-free detection of waterborne pathogens.

View Article and Find Full Text PDF

Potentiometric sensors with nanostructural ion-selective membranes were prepared and tested. Electrospun nanofiber mats were applied in novel all-solid-state sensors, using carbon paper as an electronically conducting support. For the sake of simplicity, application of a solid contact layer was avoided, and redox-active impurities naturally present in the carbon paper have proven to be effective as ion-to-electron transducers.

View Article and Find Full Text PDF

A Silicon-Based Field-Effect Biosensor for Drug-Induced Cardiac Extracellular Calcium Ion Change Detection.

Biosensors (Basel)

December 2023

Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China.

Calcium ions participate in the regulation of almost all biological functions of the body, especially in cardiac excitation-contraction coupling, acting as vital signaling through ion channels. Various cardiovascular drugs exert their effects via affecting the ion channels on the cell membrane. The current strategies for calcium ion monitoring are mainly based on fluorescent probes, which are commonly used for intracellular calcium ion detection (calcium imaging) and cannot achieve long-term monitoring.

View Article and Find Full Text PDF
Article Synopsis
  • - A new, affordable potentiometric sensor for detecting erythromycin (ERY) uses circular carbon dots and incorporates nanomaterials (f-MWCNTs/PANi) to improve performance, offering high sensitivity and selectivity against other similar drugs.
  • - The sensor operates with a detection limit of 9.6 ± 0.4 × 10 M and shows excellent selectivity when tested against related substances like azithromycin and paracetamol, making it suitable for accurate drug monitoring.
  • - Validated for use in pharmaceutical formulations and human urine samples, the sensor demonstrates recovery rates between 93.0% and 104.3%, showcasing its effectiveness even in complex biological matrices with minimal sample volume needed.
View Article and Find Full Text PDF

Application of Metal Oxide Nanoparticles in the Field of Potentiometric Sensors: A Review.

Membranes (Basel)

November 2023

Faculty of Materials Science and Ceramics, AGH University of Krakow, Mickiewicza 30, PL-30059 Krakow, Poland.

Article Synopsis
  • Recent advancements in electrochemical sensors highlight their improved performance, affordability, and ease of use, making them popular alternatives to traditional analytical tools.
  • The review emphasizes the role of various metal oxides in creating potentiometric sensors, leveraging their high electrical capacity and mixed ion-electron conductivity for effective sensing applications.
  • The paper evaluates different metal oxide materials and designs, showcasing how they enable the development of competitive all-solid-state potentiometric sensors with outstanding analytical properties.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!