This study evaluated the resistance to flexural fatigue and torsional strength of files for glide path preparation in continuous rotation or Optimum Glide Path motion (OGP). ScoutRace 15.02 and ProGlider 16.02 files were used in a dynamic testing device during preparation of simulating curved root canals (40-degree curvature and 5 mm radius). For the torsional test, a machine was used to test torsion measured maximum torsional strength (N.cm). Two-way anova and Tukey's multiple comparisons test were used for statistical analysis. Files in OGP motion had a statistically better resistance to flexural fatigue (P < 0.05). ProGlider files took longer time to failure than ScoutRace files only when OGP was used (P < 0.05). The torsional test revealed that OGP produced significantly less torsional stress than rotary motions for both types of glide path files (P < 0.05) In conclusion, OGP motion increased substantially the mechanical safety of endodontic glide path files.

Download full-text PDF

Source
http://dx.doi.org/10.1111/aej.12519DOI Listing

Publication Analysis

Top Keywords

glide path
16
optimum glide
8
path motion
8
continuous rotation
8
files glide
8
path preparation
8
resistance flexural
8
flexural fatigue
8
torsional strength
8
path
4

Similar Publications

Comparison of mechanical properties and shaping performance of ProGlider and ProTaper ultimate slider.

BMC Oral Health

January 2025

Department of Conservative Dentistry, College of Dentistry, Kyung Hee University, 26-6, Kyungheedae-ro, Dongdaemun-gu, Seoul, 02453, Republic of Korea.

Background: This study aims to compare design, phase transformation behavior, and torsional resistance of the ProGlider (PG) and ProTaper ultimate slider (PUS) and to compare the performance of two files in the glide-path preparation of a double-curved artificial canal.

Methods: Scanning electron microscopy, micro-computed tomography, and differential scanning calorimetry were used to characterize the samples. A torsional resistance test was performed to obtain ultimate strength and distortion angle.

View Article and Find Full Text PDF

Aim: All commercial chelating gels contain EDTA which reacts chemically with sodium hypochlorite (NaOCl). This research aimed to develop a non-EDTA clodronate gel and to measure physicochemical and functional gel properties of the novel and commercial gels.

Methodology: A 1.

View Article and Find Full Text PDF

This study assessed the impact of pre-enlarging the root canal using a size 25 K-file on the fracture incidence of three reciprocating instruments after multiple uses. After a glide path performed with a size 15 K-file, the instruments (Reciproc R25, Reciproc Blue R25, and WaveOne Gold Primary) were initially used in 936 root canals. Then, for the second and third uses (933 and 927, respectively), a pre-enlargement using a size 25 K-file at the working length was done.

View Article and Find Full Text PDF

Influence of plasma-enhanced combustion on RBCC engine using URANS.

Sci Rep

December 2024

State Key Laboratory for Strength and Vibration of Mechanical Structures, Shaanxi Engineering Laboratory for Vibration Control of Aerospace Structures, School of Aerospace, Xi'an Jiaotong University, Xi'an, 710049, People's Republic of China.

Article Synopsis
  • - The RBCC engine is a promising propulsion system for launching vehicles into orbit, but maintaining efficient combustion during mode transitions is challenging due to low incoming flow temperatures.
  • - New research proposes using plasma combustion support to enhance RBCC engine performance during these mode transitions, particularly from ejector/ramjet to ramjet/scramjet modes.
  • - Numerical simulations indicate that adding arc plasma increases heat release and thrust while reducing aerodynamic drag during transitions, and it also stabilizes thrust fluctuations and decreases transition times at high Mach numbers.
View Article and Find Full Text PDF

Aim The aim of the present study was to evaluate the in vitro comparative assessment of root canal centering ratio and canal transportation associated with ProTaper Universal (PTU) (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (PTN) (Dentsply Maillefer, Ballaigues, Switzerland), and ProTaper Gold (PTG) (Dentsply Tulsa Dental Specialties, Tulsa, OK, USA) rotary file systems, with or without glide-path preparation, using cone beam computed tomography (CBCT) analysis. Materials and methods A total of 120 mesial roots of extracted human mandibular first molar teeth were collected and randomly divided into three groups (n = 40) depending on the type of rotary file system used for mesiobuccal root canal instrumentation: Group 1: PTU, Group 2: PTN, and Group 3: PTG rotary file systems. Each group was further divided into two Sub-groups (a and b) with 20 specimens, depending on whether glide-path preparation was performed using the ProGlider (PG) file (Dentsply Maillefer, Ballaigues, Switzerland).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!