Unicompartmental knee arthroplasty has been shown to provide superior functional outcomes compared to total knee arthroplasty and have motivated development of advanced implant designs including bicruciate retaining knee arthroplasty. However, few validated frameworks are available to directly compare the effect of implant design and surgical techniques on ligament function and joint kinematics. In the present study, the subject-specific lower extremity models were developed based on musculoskeletal modeling framework using force-dependent kinematics method, and validated against in vivo telemetric data. The experiment data of two subjects who underwent TKA were obtained from the SimTK "Grand Challenge Competition" repository, and integrated into the subject-specific lower extremity model. Five walking gait trials and three different knee implant models for each subject were used as partial inputs for the model to predict knee biomechanics for unicompartmental, bicruciate retaining, and total knee arthroplasty. The results showed no significant differences in the tibiofemoral contact forces or angular kinematic parameters between three groups. However, unicompartmental knee arthroplasty demonstrated significantly more posterior tibial location between 0% and 40% of the gait cycle ( < 0.017). Significant differences in range of tibiofemoral anterior/posterior translation and medial/lateral translation were also observed between unicompartmental and bicruciate retaining arthroplasty ( < 0.017). Peak values of anterior cruciate ligament forces differed between unicompartmental and bicruciate retaining arthroplasty from 10% to 30% of the gait cycle. Findings of this study indicate that unicompartmental and bicruciate retaining arthroplasty do not have identical biomechanics and point to the complementary role of anterior cruciate ligament and articular geometry in guiding knee function. Further, the patient-specific musculoskeletal model developed provides a reliable framework for assessing new implant designs, and effect of surgical techniques on knee biomechanics following arthroplasty.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/09544119211011827 | DOI Listing |
Orthopadie (Heidelb)
January 2025
Klinik für Orthopädie und Unfallchirurgie, Universitätsklinikum Freiburg, Medizinische Fakultät, Albert-Ludwigs-Universität Freiburg, Freiburg, Deutschland.
Background: Patients who have had prior injections, surgeries such as arthroscopies, and have existing osteosynthetic implants in the hip and knee have an increased risk of periprosthetic infections when undergoing hip (THA) or total knee arthroplasty (TKA).
Osteosynthesis: For patients with osteosynthetic implants in the knee joint, a two-stage procedure (implant removal followed by TKA) is recommended based on the available literature and the high colonization rates. A two-stage procedure is also recommended for patients with hip implants.
Agri
January 2025
Department of Anesthesiology and Reanimation, Ege University Faculty of Medicine, İzmir, Türkiye.
Stromal vascular fraction (SVF) is a heterogeneous collection of cells obtained from adipose tissue through lipoaspiration and is an alter-native intraarticular treatment option, especially in osteoarthritis (OA). The anti-inflammatory and extracellular tissue repair-stimulating properties of SVF increase its effectiveness in regeneration and repair mechanisms. One of the most common symptoms of hemophilia A and B is hemophilic arthropathy (HA).
View Article and Find Full Text PDFSICOT J
January 2025
Department of Orthopedic Surgery and Sport Medicine, Croix-Rousse Hospital, FIFA Medical Center of Excellence, 69004 Lyon, France - Université de Lyon, Université Claude Bernard Lyon 1, IFSTTAR, LBMC UMR_T9406, 69622 Lyon, France.
Introduction: Revision Total Knee Arthroplasty (RTKA) is complex, and induced bone loss might endanger implant fixation and joint stability. Intramedullary stems improve fixation throughout stress redistribution. The current study aims to compare the performance of short tibial stems with long tibial stems, investigating their intermediate-term radiographic and survival outcomes in RTKA.
View Article and Find Full Text PDFArthroplast Today
February 2025
Department of Orthopaedic Surgery, McLaren-Flint, Flint, MI, USA.
Background: Reducing unnecessary emergency department (ED) visits following joint arthroplasty is an important goal. Literature suggests 30-day visit rates range between 4% and 15%, with only 20%-25% of these admitted for care. Low admissions suggest an opportunity to reduce unnecessary postarthroplasty ED visits.
View Article and Find Full Text PDFFront Med (Lausanne)
January 2025
Department of Knee Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, Xi'an, China.
Purpose: The purpose of this investigation is to assess and contrast the effectiveness of the two EuroQol five dimensions questionnaire (EQ-5D) versions-EQ-5D-3L and EQ-5D-5L-in assessing one-year quality of life outcomes for patients with knee osteoarthritis (KOA) undergoing unicompartmental knee arthroplasty (UKA).
Material And Method: From the medical records at the Honghui Hospital, Xi'an Jiaotong University, 402 individuals aged 50 and above, who were one-year post-operation, were selected to fill out survey questionnaires during their return hospital visits. Of these, 231 respondents (57.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!