Purpose: The aim of this study was to evaluate the survival and success rates of oral rehabilitations in a shortened maxillary dental arch and expanded maxillary sinus with 4-mm extrashort implants splinted to longer ones.
Materials And Methods: One 10-mm and one/two extrashort 4-mm titanium-zirconium SLActive tissue-level dental implants were inserted into 11 patients with limited vertical bone availability due to an expanded maxillary sinus antrum. Immediately and 6 months after insertion, implant stability resonance frequency analysis (RFA) values were assessed with an Osstell device. Splinted crowns combining 4- and 10-mm implants were supplied to all 11 cases.
Results: In 10 cases, the bone quality was type III, and in one case, type IV. Among 17 4-mm and 11 10-mm implants, the median RFA values were 61 (interquartile ranges [IQR]: 59 to 64) and 66 (IQR: 64 to 72). One 4-mm implant failed to osseointegrate and was removed. After 6 months of healing, secondary-stability measurements of 16 of the remaining 4-mm implants increased to 68 (IQR: 62 to 72) and of 10-mm implants to 78 (IQR: 77 to 80). After 1 year, all (11/11) oral rehabilitations supported by 10-mm (11/11) and 4-mm (16/16) implants were functional. The medians and IQRs of the probing depths (median: 2.8 mm, IQR: 2.3 to 3.1 mm vs median: 2.9 mm, IQR: 2.4 to 3.1 mm) and the crestal bone loss (median: 0.75 mm, IQR: 0 to 0.9 mm vs median: 0.22 mm, IQR: 0 to 0.4 mm) for the 10-mm and 4-mm implants, respectively, were similar.
Conclusion: Rehabilitations with splinted crowns combining 4- and 10-mm implants demonstrated a favorable 1-year performance in a shortened maxillary dental arch.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.11607/jomi.8645 | DOI Listing |
Sensors (Basel)
December 2024
CMEMS-UMinho, University of Minho, 4800-058 Guimarães, Portugal.
In biomedical research, telemetry is used to take automated physiological measurements wirelessly from animals, as it reduces their stress and allows recordings for large data collection over long periods. The ability to transmit high-throughput data from an in-body device (e.g.
View Article and Find Full Text PDFObjectives: To compare lag-screw slide and revision surgery rate between two generations of the Stryker Gamma cephalomedullary nail (Stryker, Kalamazoo, MI).
Methods: Design: Retrospective chart review.
Setting: Single academic, Level-1 Trauma Center.
Mater Today Bio
February 2025
Department of Orthopedics and Trauma, Peking University People's Hospital, Beijing, 100044, China.
Recent advancements in tissue engineering have promoted the development of nerve guidance conduits (NGCs) that significantly enhance peripheral nerve injury treatment, improving outcomes and recovery rates. However, utilising tailored biomimetic three-dimensional (3D) topological porous structures combined with multiple bio-effect neurotrophic factors to create environments similar to neural tissues, regulate local immune responses, and develop a supportive microenvironment to promote peripheral nerve regeneration and repair poses significant challenges. Herein, a biomimetic extracellular matrix (ECM) NGC featuring an interconnected 3D porous network and sustained delivery of insulin-like growth factor-1 (IGF-1) is designed using multi-functional gelatine microcapsules (GMs).
View Article and Find Full Text PDFActa Orthop
January 2025
Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands.
Background And Purpose: This study updates 2 parallel systematic reviews and meta-analyses from 2012, which established the 1-year radiostereometric (RSA) migration thresholds for tibial components of total knee replacements (TKR) based on the risk of late revision for aseptic loosening from survival studies. The primary aim of this study was to determine the (mis)categorization rate of the 2012 thresholds using the updated review as a validation dataset. Secondary aims were evaluation of 6-month migration, mean continuous (1- to 2-year) migration, and fixation-specific thresholds for tibial component migration.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
December 2024
Sezione di Chirurgia Protesica ad Indirizzo Robotico, Unità di Traumatologia Dello Sport, UOC Ortopedia e Traumatologia, Brescia, Italy.
Purpose: The application of robotics in revision arthroplasty particularly from unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA), is underexplored. The purpose of this study is to describe the surgical technique of an imageless robotic system used in the revision of UKA to TKA and to evaluate short- to mid-term outcomes.
Methods: This prospective study includes 35 patients treated from May 2020 to July 2023.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!