In the case of the degeneration of surgical aortic valve replacement (SAVR), the transcatheter aortic valve implantation (TAVI) has become the standard. However, these valves are also susceptible to deterioration. In such instances, a new TAVI implantation may be considered.

View Article and Find Full Text PDF

Coronary obstruction remains a primary concern for redo transcatheter aortic valve implantation (TAVI) due to supra-annular leaflets. Hereby, we present two valve-in-valve-in-valve cases, initially incorporating a surgical valve implanted to clarify our concept that the surgical valve serves to safeguard against the coronary ostium obstruction.

View Article and Find Full Text PDF

• Transseptal MV implantation is performed for many indications. • Previous ViV procedures do not preclude further ViV insertion. • Appropriate sizing of transseptal MVs is essential to reduce complications.

View Article and Find Full Text PDF

This study examines a complex scenario of structural valve degeneration (SVD) in a high surgical-risk patient with a previously implanted 25 mm Carpentier-Edwards (CE) Perimount Magna Ease 3300 (Irvine, CA: Edwards Lifesciences) surgical bioprosthetic valve (SAV), the patient presented with both paravalvular leak (PVL) and central prosthetic valve insufficiency (PVI). The patient was considered for a transaortic valve-in-valve (ViV) intervention with a self-expanding 29 mm Evolut R valve (Minneapolis, MN: Medtronic). The case describes a ViV intervention complicated by the malpositioning of the Evolut R valve secondary to micro-dislodgement into the left ventricular outflow tract (LVOT) after deployment and subsequent migration into the LVOT during an attempted bioprosthetic valve fracture (BVF) of the SAV that aimed to decrease transvalvular gradients.

View Article and Find Full Text PDF

Transcatheter mitral valve replacement (TMVR) has emerged as a feasible alternative to surgical reoperation in failed bioprostheses and rings. Residual mitral regurgitation following TMVR can present as a valve-in-valve paravalvular leak (PVL) and is associated with increased morbidity and mortality. Current therapies for valve-in-valve PVL are limited.

View Article and Find Full Text PDF